Herunterladen Inhalt Inhalt Diese Seite drucken

Taking Out Of Service And Disposal; Technical Specifications - INDUS classic 74-312 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INDUS classic 74-312
Inductive signal transmission system

10 Taking out of service and disposal

The products manufactured by ASO are intended solely for commercial use (B2B) At the end of use,
the products are to be disposed of according to all local, regional and national regulations Products
can also be returned to ASO, which will then dispose of them properly

11 Technical specifications

Supply voltage
Mains voltage:
Low voltage:
Power consumption
Terminal resistance of the safety contact edges
nominal value
upper switching point
lower switching point
Nominal current DC
Nominal current AC
Mech life-time
Switching off delay (response time)
Switching on delay
protection
Housing
Dimensions (HxWxD)
Housing
Housing incl cable clamps
Protection class
Weight
460 g
Temperature range
Connection cable cross-section
single- or fine-stranded cable 0,75-1,5 mm
Certifications
Electronics
Electromechanics
Safety device acc to DIN EN 12978
All voltages connected to the switching unit must be safely
isolated!
U
230 V AC 50/60 Hz
mains
U
24 V AC/DC ±10 %
E
P
3 VA
max
Stationary
Travelling
contact edge
contact edge
R
= 8,2 kΩ
nom
R
> 12 kΩ
AO
R
< 5 kΩ
AU
2 A
24 V DC
2 A
30 V AC
>10
actuations
6
Stationary
contact edge
< 10 ms
500 ms (Power on 700 ms)
2A time lag (glass tube 5x20)
Polystyrene with transparent cover
80 x 120 x 55 mm
102 x 120 x 55 mm
IP65
-20°C to +55°C
2
DIN EN ISO 13849-1:2008 Category 3 PL e
MTTFd 170 years, DC 91%
MTTFd 1616 years, DC 99 %
B10d 1000000
MTTFd 190 years (Nop 52560)
= 8,2 kΩ
> 20 kΩ
< 2,5 kΩ
Travelling
contact edge
< 30 ms
EC type-examination no.:
44 205 12 399386
Certificate no.:
44 780 12 399386
Test report no.:
12 205 399386-000
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis