1- The CO2 tank equipped with a siphon tube is required for the proper operation of this product.
Maintenance
If the frosting time exceeds 10 seconds, it indicates that the CO2 cylinder needs to be replaced.
1.
Close the shut-off valve on the CO2 cylinder.
2.
Press the blue button on the product to release any remaining pressure.
3.
Loosen the nut on the CO2 cylinder and remove the empty cylinder.
4.
Install a new, full CO2 cylinder.
5.
Wrap the steel wire of the connection hose around the CO2 tank.
6.
Place rubber seal rings inside the connection hose nut, then connect the hose to the CO2 tank.
7.
Hand-tighten the nut, then use a wrench to finish tightening.
NOTE: DO NOT overtighten.
8.
Slowly open the CO2 tank to check for any leaks, then fully open it.
9.
Press the blue button to verify that the equipment is functioning properly.
Disposing of used devices
Do not dispose of this device in municipal waste systems. Hand it over to an electric and electrical device
recycling and collection point. Check the symbol on the product, instruction manual and packaging. The plastics
used to construct the device can be recycled in accordance with their markings. By choosing to recycle you are
making a significant contribution to the protection of our environment.
Contact local authorities for information on your local recycling facility.
Troubleshooting
Problem
EN
Solution