Servicing Settings
Preparation
Setting
Picture amplitude
Test
card
Picture
linearity
Test
card
Test
car
Picture
frequency
Test
card
Line frequency
Test
card
Line linearity
High tension
voltage
Test
card
Brightness
Test
card
Picture
width
Test
card
Picture
shift horiz.
Test card with grid
EIW amplitude
Test card with grid
EIW
raster
Test
card
Focus
PAL-SECAM-
Alignment
Passage curve
Bell-shaped fileter
1st possibility
Bell-shaped filter
2nd possibility
switch off UG 2,
Grey tuning
controls
in mid position
connect
on IF-module
switch
switch
White tuning
set contrast
short
Colour
carrier
(F-module)
Delay line amplitude
Standard
Standard
Delay time phase
SECAM identification
SECAM
The equipment must be allowed to operate for approx. 10 minutes before adjustments are made.
Instrument
with
circle
with
circle
with
circle
Voltmeter
minimum
with
circle
with
circle
Video
wobbulator
Scope
Scope
Scope
Scope
Scope
Oscilloscope
R 754/756
pin 2 and 3
Voltmeter
on UG 2
Oscilloscope
off UG 2,
control
to max.
Oscilloscope
Oscilloscope
circuit
F IIF
2 and
F 3/F 4
colour
test
card
colour
test
card
Oscilloscope
test card
Measure
pt.
Setting
procedure
set withcontrolR321 @
set withcontrolR312 @
set withcontrolR309 @
short circuit pin 3 of V-board to ground
set with
control
R 438
short circuit measurement
MP 01 IMP 02
setwithcoil L 1023 @
set 155Vwith controlR623 E]
(corresponds
to 26 kV)
set with
control
R 396
set with
control
R 427
set with
control
R 385
set with
control
R 386
set with the control
Pin I
set suction
hole to 6 MHz with
(F-module)
R 737
MP F 1 (Pin 23,
set max. 5 MHZ With
TDA 3510)
R 737
set suction
hole to 4,1 MHz with L 709
set suction
hole to 5,5 MHz with L 707
set a straight passage curve between 4,1 MHz
and 5,5 MHz with L 708
Pin 2.
set to max. 4,286
TDA 3520
Pin 2,
align differences
TDA 3520
minimum
with
L 702
B 11B 21B 3
with controls
R838
set clamp connection
(see oscillogram)
Check point
with brightness control set to 150 V
set controls R 946, R 947, R 948 such that agrey
line is just discernable
set with control R 851 picture amplitude
100 vss
set with control R 756 picture amplitude
100 vss
set with control R 754 picture amplitude
100 vss
with
trimmer
C 708
set venetian
effect
sectors
with
control
set venetian
effect
barrier
with coils L 704, L 706
MP F 11 (Pin 6,
set d.c. potential to minimum with coil L 703
TDA 3520)
points
on the tripler
L 707
L 701
MHz with L 702
of amplitudes
in line to
(B 1), R822 (B
(B 3)
to 170 V
set colour
carrier
to fo
minimum
in the Antipal
R 708
minimum
in the
colour
170 v
clamping
point