Herunterladen Diese Seite drucken

Technical Data; Scope Of Delivery; Installation; General Installation Information - T.I.P. BRIO 2000 M Gebrauchsanweisung

Elektronische pumpensteuerung
Vorschau ausblenden Andere Handbücher für BRIO 2000 M:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
2000 M electronic pump control will delay cutting-out by 7 to 15 seconds. This method will decrease the cut-in/cut-
out frequency of the pump at low flow rates and thus contribute to a sparing operation of the unit. This feature is
also activated in the case of the pump's dry-running and thus protects the device efficiently from damage which
may be caused by operation in the absence of water.
The cut-in pressure and the pressure inside the pipe system can be checked using the built-in pressure gauge.
When using the Brio 2000 M, the liquids to be discharged must not contain any solids since this may entail
functional disturbances. If this cannot be excluded, please use an efficient prefilter at the intake area of the pump.
The unit is not suited to discharge saltwater, faeces, inflammable, etching, explosive or other
hazardous liquids. Please observe the max. and min. temperatures of the liquids to be
discharged stated in the technical data.
3.

Technical Data

Model
Mains voltage / frequency
Max. current strength for connection socket
Protection type
Intake port
Outlet port
Max. operating pressure
Cut-in pressure setting range
Preset default cut-in pressure
Max. size of the solids being pumped
Min. fluid temperature
Max. fluid temperature (T
)
max
Length of connection cable
Cable type
Weight (net)
Dimensions (L x D x H)
Item no.
4.

Scope of delivery

The scope of the delivery of this product includes:
One electronic pump control with a connection cord, one double nipple, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5.

Installation

5.1.

General installation information

During the entire process of installation, the devices must not be connected to the electrical
mains.
The pump, the Brio 2000 M electronic pump control and the entire collection system have to
be protected from frost and weather influence.
When installing the unit, please make sure that the connection cable is not subjected to
excessive pulling strain since this may cause damage to the electrical line and the electrical
connector.
When the pump stops in normal operation, the pipe system is under pressure. Therefore, a
consumer is to be opened prior to any intervention to make sure that the pressure will be
relieved.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and
cause considerable damage. Therefore, please use Teflon tape to seal the contact surfaces between the
threaded sections of the lines and the connection with the pump. This use of sealing material such as Teflon tape
is the only way to ensure an airtight assembly.
When tightening threaded connections, please do not apply excessive force which may cause damage.
8
Brio 2000 M
230 V ~ 50 Hz
12 A
IP 65
30.93 mm
(1 "), female, rotating
33.25 mm
(1 "), male
10 bar
1.0 - 3.5 bar
1.5 bar
0 mm
2 °C
55 °C
1.5 m
H07RN-F
0.75 kg
10 x 10 x 19.5 cm
30241
2