5. Necessary materials
A MAGNUM Mat System.
Flexible tile adhesive or Self levelling
compound and flexible grout suitable for
floor heating.
Flexible cement and cement gun for
expansion joints along the walls.
2m flexible electrical conduit (16mm).
Plastic adhesive comb with 6mm teeth.
Electrical back box (min. 35mm deep,
preferably 50mm).
Earthed power connection.
A multimeter to test the mat after each
installation activity.
6. Preparations
Determine where the thermostat must be
placed, place a standard electrical back box with
a minimum depth of 35mm, preferably at a
height of 1.40 m for ease of operation. Grind/cut
the necessary grooves and mount the junction
box and electrical conduit.
2 conduits have to be installed; One for the
sensor and the other for the power cable from
mat. Do not run the power cable and sensor
cable through the same conduit. Cut a groove in
the floor for the floor sensor pipe (2 cm deep).
TAKE CARE: Never place the sensor in the vicinity
of a (hidden) radiator pipe! Never install it
passing under a heating cable!
Ensure that the surface where the mat is worked
on is flat, clean, and free of dust and grease. In
larger spaces, expansion joints along the wall
may have to be used.
7. Resistance readings
Before installing the MAGNUM Mat, the
resistance reading should be taken and
noted down on the inspection card in the
center of this manual. The reading should
MAGNUM Mat
11
loading