Assembly
WARNING:
• When assembling or inserting the extraction filter as well as the carbon filter, the appliance must not be connected to the mains.
• Failure to use the mounting fixtures may lead to a risk of electric shock.
CAUTION:
• Before mounting, check that the wall and/or wall unit has the load capacity to bear the extractor hood.
• When drilling the holes in the wall always make sure that no existing electrical cables or other objects are damaged.
• Make sure that the vents are clear of obstacles and are not covered.
NOTE: Recommendations for preparation work
• When installing, ask another person to assist.
• Wear protective gloves to prevent injuries from any sharp edges.
1
• The hood is mounted below a suitable wall unit. Determine the position of the extractor hood centrally above the hob in conformance with the
specified safety distances.
• Pull the pull-out device and remove the aluminium grease filter.
• Hold the hood to the specified cabinet position and draw the drilling points from the inside of the unit corresponding to the six screw holes. Check
them with a spirit level.
• For extraction mode, you must also create a feed through of approx. Ø 130 mm in the base of the unit.
• If the mains cable is fed through the unit, a feed through also must be provided.
• Drill six mounting holes of Ø 4 mm through the base of the unit.
• Screw in the appliance with the screws (1) and washers under the wall unit.
• Insert the fitting with non-return valves (2) onto the extraction duct from above. Make sure that the mounting hooks on the fitting latch into place.
• For extraction mode, a flexible extraction hose (not supplied) with an inner diameter of Ø 120 mm must be fitted and connected to the outside by
an extraction vent.
• To fill the gap between the wall and the appliance, attach the spacer strip on the narrow or wide side, depending on the gap. Mount the strip using
the screws (3) in the holes provided on the appliance.
• Reinstall the aluminium grease filter.
Installing the activated carbon filter for recirculation mode
• Pull the pull-out device and remove the aluminium grease filter.
• Place the carbon filter onto the air intake of the extraction duct. Make sure that the mounting pins on the extraction duct engage the
mounting slots of the carbon filter. Turn the respective filter clockwise until it clicks into place.
• Reinstall the aluminium grease filter.
NOTE:
The activated carbon filter absorbs odours and must be replaced at least every six months depending on use.