Herunterladen Inhalt Inhalt Diese Seite drucken

Requirements For The Installation Site; Fig.2 Cross-Section Of The Unit - Igloo Innova T 74 Handbuch

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

740

Fig.2 Cross-section of the unit

3. INSTALLATION AND OPERATING MANUAL

3.1. Requirements for the installation site

The unit should be placed in a dry, well-ventilated area away from sunlight, with good air exchange (distance between
the wall and the unit at least 10 cm), away from heat sources and air circulation devices (air conditioners, ceiling or por-
table fans - they CANNOT blow or extract air from the refrigeration unit!). The unit functions correctly in an environment
where the temperature is in the appropriate climate class, as indicated on the rating plate. The operation of the device
may deteriorate when it has been operating at a temperature higher or lower than the specified range for a longer period
of time, in which the temperature is in the appropriate climate class indicated on the nameplate. The operation of the
device may deteriorate when it has been operating at a temperature higher or lower than the specified range for a longer
period of time.
DO NOT COVER THE VENTS
WENTYLACYJNYCH!!!
16
User manual INNOVA T
FIXED SHELVES
740
400
Fig.3 Appropriate positioning of the unit - to ensure proper
ventilation
3.2. Podłączenie do instalacji elektrycznej
Verify that the voltage and frequency in the network match tho-
se recommended by the manufacturer (see rating plate).
Make sure that the cross-section of the power cables is su-
itable
for the power consumption of the equipment being installed
It is forbidden to connect the device via extension cables or
switchgears
The device must be connected to a separate, properly
wired electrical circuit with a plug-in socket with protective pin
(as per PBUE)
ROTATING SHELVES
538
en
www.igloo.pl