6. Single and double temperature zone function
This product automatically identifies the temperature zone. By inserting the middle
partition, the default configuration is the double temperature zone. The left zone serves
as the freezing zone, whilst the right zone serves as the refrigeration zone. In this
configuration, the freezing zone temperature is adjustable.
When the middle partition is removed, it becomes a single temperature zone. The
temperature is set to the desired value.
Cleaning and maintenance
Before cleaning, unplug the appliance and wipe the inner and outer surfaces with a
damp cleaning cloth. Do not clean this appliance directly with water – this can damage
electrical components.
When not in use for long periods, ensure you clean the inside and outside of the
refrigerator and keep it dry.
Error code description
If there is an abnormality in the compressor, module, fan, temperature sensing head or
input voltage, an error code will display on the screen and the compressor will stop
working. To solve this problem, unplug the power supply and plug it back in. The
refrigerator temperature display will return, and after one minute, the compressor will
start in refrigeration mode again.
The code description is shown in the table below:
Error code
The temperature sensing head is
E 0
E 1
E 2
DC fan over current protection
E 3
Abnormal start of compressor
E 4
Abnormal compressor speed
E 5
Module temperature too high
E 6
Problem
damaged
Input voltage is too low
Module hardware failure
Please check or replace the
temperature sensor
Please check the input voltage
and adjust the battery protection
Please check the cooling fan
Please turn o ffthe power and let it
stand for 30 minutes
Please adjust compressor
operation mode (MAX/ECO)
Please move the refrigerator to a
ventilated place to lower the
module temperature
Power on after 30 minutes of
power failure, if the fault is not
eliminated, the module needs to
8
Solution
level
be replaced