Using the device
Open the battery compartment of your weather station unit. Insert 2 AAA batteries respecting the
polarity and then close the battery compartment lid.
After powering on, the LCD screen will turn on for 3 seconds and then switch to default display mode.
Operation of the external probe
Open the battery compartment of your probe unit (pt. 12 fig. 2). Insert 2 AAA batteries respecting the
polarity and then close the battery compartment lid. The weather station will now search for the DCF
signal for 3 minutes
The strength of the outdoor signal will be displayed on the station's screen. If there are no bars or if the
bars are not displayed at their maximum intensity, move the radio station and probe for a better
connection.
To start receiving the DCF signal manually, press and hold the "+" button on the station (pt.3 fig.1) for two
seconds. If no signal is received within 7 minutes, the DCF signal search stops (the radio mast icon
disappears) and starts again at the next full hour. This procedure is repeated automatically up to a total
of 5 times. To stop searching for the signal, press and hold the "+" button for two seconds.
Mode button:
Press and hold the mode button for 2 seconds to access the various settings. Each time you press the
mode button you will be taken to the following setting and will be displayed in the following order:
-
Setting the temperature unit in °C or °F: Now use the "+" and "-" buttons to set the temperature unit in
°C or °F you need.
-
Weather Forecast: Now use the "+" and "-" buttons to set the weather forecast mode you need.
-
Automatic time reception: Now use the "+" and "-" buttons to set the automatic "ON" or manual "OFF"
time mode.
Manual time and date setting:
Press the "SET" button to confirm your setting, the 12/24HR format will flash. Now use the "+" and "-"
buttons to set the 12/24-hour mode.
Press "SET" to confirm your setting, the time display will start flashing. Now use the "+" and "-" buttons to
set the correct time. Do the same to set the minutes, date, month, year, language
Press "SET" to complete the setting procedures.
Alarm setting:
Press the "+" button once, the LCD display will display the icon, the alarm function is on, then press the "+"
button once, the icon
Press the "SET" button once, the alarm time is displayed, then press and hold the "SET" button for 2
seconds until the alarm time starts flashing. Use the "+" and "-" buttons to set the required time. Do the
same for the minutes. Press the "SET" button to confirm your setting.
When the alarm sounds, press any button except the "SNOOZE/LIGHT" button to stop the alarm signal.
When the alarm sounds, press the "SNOOZE/LIGHT" button to switch the alarm mode to snooze mode. The
alarm will sound again after the time you have determined has passed.
Temperature/Humidity Function
Indoor temperature detection range: -9.9°C ~ +50°C and +14.1°F ~ +122°F, display resolution: 0.1°C and °F.
When the detection interior temperature is below -9.9 °C and +14.1 °F it is displayed as LL.L °C&°F, and
when it is above +50 °C and +122 °F, it is displayed as HH. H °C and °F.
Outdoor temperature detection range: -40°C ~ + 70°C and -40°F ~ + 158°F, display resolution: 0.1°C and
°F.
When the outdoor temperature of detection is below -40°C and -40°F, it is displayed as LL.L°C and °F, and
when it is above +70°C and +158°F, it is displayed as HH. H °C and °F. The temperature detection cycle is
will disappear from the display, the alarm function is disabled.
www.livoo.fr