8. Change of the dosage / 9. Pump removal

8. Change of the dosage

The dosage of the pump is adjusted to the maximum of
approx. 1.5 ml/stroke. If required the dosage can be reduced
in stages by turning the dosage piece (part of the pump)
up to approx. 0,75 ml/stroke.
For this remove the pump from the dispenser.

9. Pump removal

Lift the outlet pipe out of the holder.
Turn the end of the outlet pipe 90° anticlockwise.
Keep the pump block pressed down with the finger and pull the
pump out to the front. Simultaneously swivel the top of dispenser
unit, to allow the pump to be removed forwards.
When inserting the pump, follow the above steps in reverse order.