Herunterladen Diese Seite drucken

Kaiser RB 551 AB Bedienungsanleitung Seite 6

Led-beleuchtungseinrichtung
Verfügbare Sprachen

Verfügbare Sprachen

with or without the soft screen. When used with the soft
screen the polarizing foil must be placed at the outside.
8. Maintenance and care
The lights are maintenance-free. Make sure that the soft
screens (6) are free of stains and dirt. If necessary remove
these before operation.
Clean the devices with a soft dry cloth. On no account use
petrol or other solvents.
9. Specifications
LED arrays:
Color temperature:
Color rendition index:
LED angle of radiation:
Max. illumination*
with soft screen:
w/o soft screen:
Max. power of LEDs:
Operating voltage:
Light emitting area
of one light:
Mains lead:
Vertical arms:
_______
* based on uniform illumination of a 16.5 x 11.5 in. flat subject
10. Accessories
5548 Polarizing foils, 2 pieces.
Right reserved to make technical modifications.
All specifications are approximate.
Disposal Instructions
Dispose unserviceable products in ac-
cordance of the relevant statutory reg-
ulations.
2 x 192 SMD LEDs
5600 K
CRI = 96
100°
4600 lux
5200 lux
2 x 24 W
AC 220 - 240 V, 50/60 Hz or
AC 120 / 277 V, 50/60 Hz
(see type plate)
39 x 16.5 cm (15.3 x 6.5 in.)
2.40 m (7.9 ft.) each
76 cm / 20 x 20 mm
(29.9 in. / 0.8 x 0.8 in.)