Herunterladen Diese Seite drucken
Fronius 3PN-63A Bedienungsanleitung
Vorschau ausblenden Andere Handbücher für 3PN-63A:
Quick
Start Guide
Fronius Backup Switch
1PN/3PN-63A
https://manuals.fronius.
com/html/4204260537
OPERATING
INSTRUCTION
42,0410,2975
003-05062025
loading

Inhaltszusammenfassung für Fronius 3PN-63A

  • Seite 1 Quick Start Guide Fronius Backup Switch 1PN/3PN-63A https://manuals.fronius. com/html/4204260537 OPERATING INSTRUCTION 42,0410,2975 003-05062025...
  • Seite 2 EN: WARNING! Incorrect operation or poorly executed work can cause serious injury or damage. Installation and commissioning must be carried out by trained personnel in accordance with the nationally applicable standards and guidelines. Before working with the device, ensure that you have read and understood all the documents printed and provided in hard copy and online. When PV modules are exposed to light, they supply voltage to the inverter.
  • Seite 3 HU: FIGYELMEZTETÉS!! A helytelen kezelés és a hibásan végzett munkák súlyos személyi sérüléseket vagy anyagi károkat okozhatnak. A telepítést és az üzembe he- lyezést csak képzett személyzet végezheti, a nemzeti szabványoknak és irányelveknek megfelelően. A készülékkel végzett munka előtt olvassa el és értse meg az összes mellékelt, nyomtatott és online elérhető...
  • Seite 4: Preparing For Installation

    Перед роботою з пристроєм прочитайте та зрозумійте всі супровідні, друковані та доступні онлайн документи! Фотовольтаїчні модулі, що піддаються впливу світла, подають напругу на інвертор. Цей документ не описує всі можливі конфігурації системи. Detailed, country-specific warranty terms are available on: www.fronius.com/solar/warranty Warning signs explanation General warning sign...
  • Seite 5: Mounting The Protective Cover

    Option: 3PN separation Connecting the data communication 8 mm (0.31 in.) Inverter Smart Meter WSD IN- 50kA-3 63A-1 CU wire conductor per 63A-3 terminal TS 5kA-3 TS 65A-3 WSD IN+ 0,13 - 2,5 mm² 0,75 - 2,5 mm² TS 100A-1 Mounting the protective cover Commissioning...
  • Seite 6 (2) Navigate to Device Configuration > Fun- ctions and I/Os (3) Activate Backup Power (4) Select Full Backup under Backup Pow- er Mode Testing the backup power function Checklist - Backup Power Grid supply https://www.fronius.com/en/ solar-energy/installers-partners/ downloads search for: „42,0426,0365“ Backup power supply...
  • Seite 8 MONITORING & DIGITAL TOOLS Fronius International GmbH Froniusstraße 1 4643 Pettenbach Austria contact@fronius.com www.fronius.com Under www.fronius.com/contact you will find the adresses of all Fronius Sales & Service Partners and locations.

Diese Anleitung auch für:

1pn-63a