door temperature.
The water circuit is properly connected (no leaks or damage to the hydraulic connections, the con-
nections are properly tightened).
The electric circuit is properly connected (the cables are tightly secured to the terminals and inter-
mediate circuit-breaker), properly insulated, and connected to the earthing connection.
The conditions of installation and use described above have all been met.
The outdoor temperature is between -3 and +43°C.
The water temperature is of 15°C minimum.
The evaporator at the rear/on the sides of the HP is clean (leaves, dust, pollen, cobwebs...)
You can now start your device by following, in the given order, the following steps:
Open the 3 valves of the bypass (refer to the hydraulic diagram).
Half-close the bypass valve.
Remove all unused items or tools from the area surrounding the HP.
Start the pump of the filtration system.
Power up the HP by engaging the circuit-breaker and using the ON/OFF button of the display.
Check that the HP starts and stops in sync with the filtration circuit: if no water is detected in the HP,
the display shows "FLO"
The HP starts after a delay of a few minutes.
Adjust the temperature ("Regulation" chapter).
Adjust the water flow ("Water flow setting" chapter).
After a few minutes, you can adjust the bypass valve as indicated in the "Water flow setting" chap-
ter. Having completed the above steps, cover the pool and let the HP operate for a few days with
the filtration pump in "forced mode" until the water of the pool reaches the desired bathing tem-
perature.

SETTINGS

Water flow setting:
To optimize the heating performance and achieve power savings, the flow of water travelling
through the HP should be adjusted.
The adjustment is done based on the reading of the water flow indicator present on the heat pump
display :.
Very low water flow
Low watre flow
Optimal water flow
High water flow
The adjustment is done by opening or closing the adjustment valve of the bypass.
To reduce the water flow: reduce the amount of water passing through the HP: open the bypass
adjustment valve.
To in crease the water flow: increase the amount of water passing through the HP: close the bypass
adjustment valve.
During normal operations, the inlet and outlet valves must remain fully open.
Normal pressure: