HYDRAULIC CONNECTION
•
Water quality necessary for this device: NF-EN-16713-3
•
The HP is compatible with all types of water treatment. The HP must imperatively be connected by a
PVC pipe of Ø 50mm to the swimming pool's hydraulic
•
Circuit, after the filter and before the treatment system, regardless of its type (Cl, pH, Br metering
pumps and/or electrolyzer).
•
Follow the hydraulic connection order (blue = water in, red = water out)
•
A bypass must be installed to facilitate work on the HP.
•
Before connecting the PVC pipes to the HP, make sure the circuit is clean of any work residue
(stone, soil, etc.).
Connection of the condensate evacuation pack:
During operations, the HP is subject to a condensation phenomenon. This translates into a water flow,
which can be more or less important depending on the degree of humidity. To channel this flow, which
can represent several litres of water per day, we recommend you install the provided condensate
evacuation pack and connect it to a suitable water evacuation circuit.
Provided connec-
tions (ø 50mm)
Evacuation of the
condensate
By-pass
Open Valve
Half-open valve
Closed valve
Bypass valve
(adjustment)
- 24 -
Water treatment (disinfec-
tion, pH correction) located
after the HP
From the swimming pool
Toward the swimming pool