Herunterladen Inhalt Inhalt Diese Seite drucken

Environmental Protection - Zgonc Yellow Gardenline YGL N.G. 400-2 Originalbetriebsanleitung

Schmutzwasserpumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Repairs
Only use accessories and spare parts
recommended by the manufacturer. If the
equipment should fail some day in spite of our
quality controls and your maintenance, only have
it repaired by an authorised electrician.

Environmental Protection

Do not simply dispose of the equipment,
accessories and packaging in the rubbish bin, but
bring it for environmentally sound recycling.
The small e ort involved in this is for the benefit of
our environment.
Faults
Pump doesn't start
Pump has no suction
Pump doesn't switch off
Discharge flow limited
Pump switches off after a short
time
Motor protection switches
pump off
Ursachen
No power
Float switch doesn'twork
Feed screen is plugged
Pressure hose buckled
Float switch can't drop
Feed screen plugged
Too dirty water reduces pump's
performance
Water is too dirty
Water temperature to high
9
Abhilfen
Check electrical plug and socket
connection
Put the float switch in a higher
position
Clean feed screen
Remove kink
Position pump correctly
Clean feed screen
Clean pump and replace closing
components
Pull the power plug, clean pump
as well as shaft
Observe maximum water
temperature

Werbung

Inhaltsverzeichnis
loading