Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

5. Troubleshooting

The fault code is displayed at the position (9 of the display screen, and the related fault type and
recovery method are asfollows.
Indicator
E102
E103
E104
E105
E107
E210
211
E212
E301
Other faults
= XX
XX
IS
the fault
number
.
Problem
• Charging low temperature
protection
: Charging high temperature
protection
: Discharge low temperature
protection
. Discharge high temperature
protection
: Total output (AC+DC)
: discharge overload
: AC discharge overcurrent
. AC discharge overload
. AC discharge short circuit
: MPPT input overvoltage
Please consult customer
Solution
Automatic recovery after ambient temperature
: recovery
: Stopcharging,check the productvents is
ventilatedor not,will automaticallyrecover
after the temperature drops down
Automatic recovery after ambient
temperature recovery
: It is recommended
for more than 2 hours, and it will automatically
recoverafter the producttemperature
drops down
Remove part of the load and tum on the
AC manually again
Remove
the load and tum on the AC
manually agan
Removethe load,tum on the AC manuallyagain,
do not use power station for the devices which
exceed the rated outputpower of the
power station
Remove the load, repair the load circuit and
tum theAC manually
Remove the solar panel, do not use a solar
panel which exceeds the rated voltage range
: of power sation to charge the power station
service for details
(15)
to shut down
and let it stand

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für ALLPOWERS R1500