Caution!
UK
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain residual
risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
• Damage to hearing if no suitable ear protection
is used.
Danger!
The electric power tool generates an
electromagnetic fi eld during operation. Under
certain circumstances this fi eld may actively or
passively impede medical implants. To reduce the
risk of serious or fatal injuries, we recommend
persons with medical implants to consult their
doctor and the manufacturer of the medical
implant prior to using the equipment.
4.2 Data for mains-powered mode
Rated operating voltage and frequency
(mains-powered) :
Rating (compressor compressed air) :
Max. operating pressure
(compressor compressed air) :
Theoretical suction rate
Rating (low-pressure blower) :
Max. volumetric fl ow for suctioning
(low-pressure blower):
Max. volumetric fl ow for infl ating
(low-pressure blower):
Compressor idling speed
Blower idling speed
4.3 Data for operation with a rechargeable
battery (without battery)
Power supply (rechargeable battery) :
Max. operating pressure
(compressor compressed air) :
Theoretical suction rate
Max. volumetric fl ow for suctioning
(low-pressure blower):
Max. volumetric fl ow for infl ating
(low-pressure blower):
Compressor idling speed :
Blower idling speed :
12
5. Before using the equipment
Before you connect the equipment to the power
supply make sure that the data on the rating
plate are identical to the supply voltage (if
operating from the mains power supply).
Before you connect the equipment to the power
supply make sure that the data on the rating plate
are identical to the data for the rechargeable
battery (if using a rechargeable battery for
operation).
• Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the compressor.
• Make sure that the intake air is dry and dustfree.
• Do not install the compressor in a damp or
wet room.
• The compressor may only be used in suitable
rooms (with good ventilation and an ambient
220-240V ~ 50 Hz
temperature from +5 °C to 40 °C). There must
60 W
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
11 bar
• The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
60 W
in areas where work is conducted with sprayed
water.
460 l/min
• Operate the equipment only on a firm, level
surface.
460 l/min
-1
3500 min
Warning! When using the equipment to inflate
-1
20000 min
objects, check the information and safety
instructions provided by the manufacturer.
5.1 Charging the LI battery pack (without
20 V d.c.
charger)
1. Remove the battery pack from the handle.
11 bar
2. Check that your mains voltage is the same as
that marked on the rating plate of the battery
charger. Insert the power plug of the charger
460 l/min
then begin to flash.
460 l/min
3. Push the battery pack onto the battery
-1
3500 min
charger .
-1
20000 min
In section 10 (Charger indicator) you will fi nd a
into the socket outlet. The green LED will