When not in use, switch off the lights with the switches (12)
and disconnect the lights from the mains by pulling out the
mains plugs.
6. Adjustments
The lighting unit can be adjusted in a variety of ways (see
fig. F, G). To adjust it, release the respective fastening
screw (6), (9) or (5) and tighten it again.
7. Changing fuse
Pull out the mains plug before changing a fuse. The fuse
can be replaced after the fuse holder (15) has been un-
screwed. The lights must only be run with the specified
fuse (F 4 A).
8. Other applications for the lights
The lights (1) can also be used as desktop or studio lights.
To do this, attach the lights to suitable stands or supports
with 16 mm (5/8") standard spigot / baby pin: Place the
lights on the standard spigot (fig. H) and lock them in place
with the screws (9). Note: The lights can also be operated
upside-down in a hanging position.
The lights can be tilted backward and forward. Hold the
light with one hand, loosen the wing screw (16) by rotating
it counter-clockwise, move the light to the desired position
and fasten the wing screw (16) again.
Always take care of a safe stand!
9. Maintenance and care
The lights are maintenance-free. Make sure that the diffus-
er screens (10) are free of stains and dirt. If necessary re-
move these before operation.
Clean the devices with a soft dry cloth. On no account use
petrol or other solvents.
10. Specifications
Light source:
2 x 200 High-CRI LEDs (SMD)
Color temperature:
5600 Kelvin
Color rendition index:
CRI: 95
Angle of radiation:
80°
Max. illumination*:
3300 lux
Light emitting area
of one light:
28 x 20 cm (11 x 7.9 in.)
Power consumption:
2 x 40 W
Operating voltage:
100 - 240 V
Fuses:
F 4 A
Mains leads:
3 m (9.8 ft.) each
Vertical arms:
73.5 cm (28.9 in.) /
20 x 20 mm (0.8 x 0.8 in.)
_______
* based on uniform illumination of a 16.5 x 11.5 in. flat subject
11. Accessories
5256 Clamp bases. For attaching the RB 5240D surface
lighting unit to regular boards up to 48 mm (1.9 in.)
thickness. 2 pieces.