4. Do not alter the ventilation space required by the device during operation.
5. If the machine will not be used for an extended period, follow these steps:
1)
Cut off the gas supply.
2)
Use a piece of cloth with petrol to clean the stainless-steel surface.
3)
Place the machine in a well-ventilated area.
Troubleshooting
Problem
The kindling is fired but the
host fire is not.
Fire set failure.
Transportation & Storage
During transportation, handle this product with care to avoid strong vibrations. Generally, the packed product
should not be stored outdoors for long periods. It should be kept in a well-ventilated warehouse free from
corrosive air. Do not store the product upside down. If outdoor storage is necessary, take appropriate measures
to protect it from rain.
EN
Possible cause
1. The pressure in the tube is not
enough.
2. The nozzle is blocked.
3. Problem with the gas switch.
4. Problem with the temperature
controller.
5. The thermocouple is not well
linked with the valve.
6. The thermocouple is out of work.
1. The pressure in the gas pipe is
not enough.
2. The nozzle is blocked.
3. Problem with the gas valve.
4. The thermocouple is wrongly
connected, or the temperature
controller is disconnected.
5. The thermocouple gets damaged
for heating kindling.
Solution
1. Change new gas.
2. Clean the nozzle.
3. change a new gas switch.
4. change
a
new
controller.
5.
Relink it.
6.
Change a new thermocouple.
1. Change new gas.
2. Clean the nozzle.
3. Change a new gas valve.
4. Reinstall it.
5. change a new thermocouple.
temperature