SPECIFICATIONS
RANGE / RESOLUTION
CD600
1990 ppm / 10 ppm
CD610
10000 ppm / 100 ppm
CD601
1990 µS/cm / 10 µS/cm
CD611
19900 µS/cm / 100 µS/cm
ACCURACY
±2% Full Scale
@ 25 °C (77 °F)
CALIBRATION SOLUTION (0ptional)
CD600 M10032B
CD610 M10038B
CD601 M10031B
CD611 M10030B
Automatic from
TEMPERATURE
5 to 50 °C
COMPENSATION
(41 to 122 °F)
5 to 50 °C
ENVIRONMENT
(41 to 122 °F)
95 % RH max.
BATTERY TYPE
4 x 1.5V alkaline
approximately
BATTERY LIFE
300 hours of use
DIMENSIONS
150 x 30 x 24 mm
WEIGHT
85 g
ACCESSORIES
MA9300 1.5V battery (10 pcs.)
Calibration screwdriver
MA9701
(20 pcs.)
12880 µS/cm calibration solution,
M10030B
20 mL sachet (25 pcs.)
1413 µS/cm calibration solution,
M10031B
20 mL sachet (25 pcs.)
1382 ppm calibration solution,
M10032B
20 mL sachet (25 pcs.)
6.44 ppt calibration solution,
M10038B
20 mL sachet (25 pcs.)
Note: Calibration solutions also available in
220 mL bottles.
CERTIFICATION
Milwaukee Instruments
conform to the CE European
Disposal of Electrical & Electronic
Equipment
Do not treat this product as household
waste. Hand it over to the appropriate
collection point for the recycling of
electrical and electronic equipment.
Disposal of waste batteries
This
product
contains
batteries. Do not dispose of
them with other household waste. Hand
them over to the appropriate collection
point for recycling.
Please note: proper product and
battery disposal prevents potential
negative consequences for human
health and the environment. For
detailed information, contact your local
household waste disposal service or go to
www.milwaukeeinstruments.com (USA
& CAN) or www.milwaukeeinst.com.
WARRANTY
These instruments are warranted against
defects in materials and manufacturing
for a period of 2 years from the date of
purchase. This warranty is limited to
repair or free of charge replacement if the
instrument cannot be repaired.
Damage due to accidents, misuse,
tampering or lack of prescribed
maintenance is not covered by warranty.
If service is required, contact your local
Milwaukee Instruments Technical Service.
If the repair is not covered by the warranty,
you will be notified of the charges incurred.
Directives.
When shipping any instrument, make
sure it is properly packaged for complete
protection.
Milwaukee Instruments reserves the
right to make improvements in design,
construction and appearance of its
products without advance notice.
ISTCD600 04/25
USER MANUAL
CD600•CD610
CD601•CD611
Digital
Conductivity & TDS Pens
milwaukeeinstruments.com
(USA & CAN)
milwaukeeinst.com
Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Milwaukee CD600

  • Seite 27: Bedienung

    Messwert auf dem Display mit dem Wert der Lösung übereinstimmt (normalerweise bei 25 °C / 77 °F). Wenn Sie z. B. das CD600 mit der Lösung M10032B kalibrieren, drehen Sie den Trimmer auf den Wert „138“ (× 10 = 1380 ppm).
  • Seite 28: Empfehlung

    Metallband zu jeder Zeit zu berühren. Um Schäden oder Verbrennungen zu vermeiden, führen Sie keine Messungen in Mikrowellenherden durch. SPEZIFIKATIONEN BEREICH / AUFLÖSUNG CD600 1990 ppm / 10 ppm CD610 10000 ppm / 100 ppm CD601 1990 µS/cm / 10 µS/cm CD611 19900 µS/cm / 100 µS/cm GENAUIGKEIT bei 25 °C (77 °F): ±2% Skalenendwert...
  • Seite 29 Ort. Wenn die Reparatur nicht von der Garantie abgedeckt ist, werden Sie über die anfallenden Kosten informiert. Achten Sie beim Versand eines Geräts darauf, dass es ordnungsgemäß verpackt ist, um es vollständig zu schützen. Milwaukee Instruments behält sich das Recht vor, das Design, die Konstruktion und das Aussehen seiner Produkte ohne vorherige Ankündigung zu verbessern.

Diese Anleitung auch für:

Cd610Cd601Cd611

Inhaltsverzeichnis