Set interval
To set the interval, press "Menu" until "Interval set" appears on the display.
Then use the Up/Down buttons to set the fog pause from 5 to 200 seconds.
This setting is required if you want to use the timer mode.
Setting the fog duration
To set the duration, press "Menu" until the display shows "Duration set".
Use the Up/Down buttons to set the fog duration from 1 to 200 seconds.
This setting is required if you want to use the timer mode.
Setting the Fog Level for Timer Mode
To set the fog quantity for the timer mode, press "Menu" until the display shows "Timer out".
Use the Up/Down buttons to set the fog quantity from 1 to 100%.
This setting is required if you want to use the timer mode.
Setting the Fog Level for Volume Mode
To adjust the fog quantity, press "Menu" until the display shows "Volume out".
Use the Up/Down buttons to adjust the fog volume from 1 to 100%.
This setting is required if you want to use the option Volume (Continuous Mode).
Setting the fan speed
To set the fan speed, press "Menu" until the display shows "Fan Speed".
Use the Up/Down buttons to set the fan speed between 1 and 100%.
Setting the DMX address
To set the DMX address, press "Menu" until the display shows "DMX ADD xxx".
Then use the Up/Down buttons to set the value from 001 to 512.
Activating/deactivating the liquid sensor
Press "Menu" until "Fluid sensor" appears in the display.
Use the Up/Down buttons to activate or deactivate the fluid sensor (On/off).
When the Fluid sensor is activated, the display shows "Ready to Fazer S".
If the Fluid sensor is deactivated, the display shows "Ready to Faze".