6. FUNCTION AND OPERATION

01. ON/OFF
The thermostat can simply be
switched On or Off by pressing the
power switch. The LED indicator
will turn On or Off.
02. TEMPERATURE SETTING
After the user sets the temperature, the thermostat keeps the floor
temperature at the set temperature. After power off, power on again,
the original set temperature will be retained and executed. Setting
range of this thermostat: 5-35°C.When the indicator is red, it means
that the thermostat is heating up.
03. ANTI FREEZE FUNCTION
Turn the knob to the leftmost postition (5°C), and the floor heating will run
at a low temperature, which can play a role in anti-freezing protection.
04. ADJUSTABLE TEMPERATURE LIMIT FUNCTION
If you want to set the maximum and minimum temperature within an ideal
range, you can manually adjust the installation position of the limit pin.
Gently remove the knob.
NOTE: When the knob is
pushed out, it is necessary to
pay attention to the direction
of the knob pointer, so that
the position is correct when it
is reinstalled.
Place the red and blue pins
in the holes of the array
in the figure to set the
temperature range you want.
For example, place the knob
pointer in the range of the
red and blue pins in the
figure, which means
that the adjustable
temperature is 10-20°C.
When installing the knob,
take care to install the
pointer position marked on
the knob to the middle of
the red and blue limit pin. In
this way, the knob is limited
to a range of 10-20° rotation.
05. TEMPERATURE TOLERANCE
The default value is 0,5°C. The thermostat start to work when the actual
temperature is 0,5°C lower than set temperature and stops working when
the actual temperature is 0,5°C higher than set temperature. This function
prevents the relay from being frequently switched on and off.
Setting method:
Temp Tolerance Value
Number represents temperature(°C)
Tolerance
0.5 1.0 1.5
Sensor selection
Remove the front shell.Three DIP switches are marked with temperature
tolerance, setback, and sensor options respectively.The following pictures
describes how to set the parameters.
Tolerance
Factory
default
0.5
1.0 1.5
Whatever value you need to set, flip the corresponding switch to the upper
"on" position.
Sometimes there are some special cases, such as the following. To avoid
this an error proof design is made to ensure that the settings are valid.
CASE 1:
When the switches are all up or all down, the setting default is 1°C.
0.5
1.0 1.5
CASE 2:
When multiple switches are above, the minimum value is taken.
0.5
1.0 1.5
06. SETBACK
Press the setback button to turn on the function. The setback function is
when the thermostat 'sets back' to a lower temperature during the off time
periods. This is the most economical and efficient way to achieve the best
energy consumption. The default value is -5°C.
07. SENSOR SELECT
Select a working sensor. When "Both" is selected, the floor sensor provides
temperature limiting protection. The maximum temperature is 30°C by
default.
Setback Temp Value
Number represents temperature(°C)
Setback
°C
°C
Floor
Room
Both
Tolerance
Tolerance
0.5
1.0
1.5
0.5 1.0
1.5
0.5
1.0 1.5
0.5
1.0
1.5
0.5
1.0 1.5
4
5
6
7
8