Fault management and maintenance
The CCE 4000 is equipped with comprehensive fault management in order to inform you about problems in the processing of
money, but also to draw attention to the contamination of sensors. Please pay particular attention to the following instructions
for cleaning the machine in order to avoid errors caused by contaminated sensors and to have an optimum result when counting
coins.
Cleaning the sensors
Due to the coins and by the settling dust, deposits occur in front of the sensors of the machine and in the transport area of the
coins. These impurities can lead to problems during transport and to the sorting of the coins.
Please clean the sensors of the CCE 4000 at regular intervals. Generally, we recommend a short cleaning at the end of the
working day, this process only takes a few minutes. When cleaning the machine, always switch off the appliance and unplug
the mains plug.
Slide the Safety-Lock switch on the back to the opened lock symbol. Turn the two side openers according to the imprint
forwards and pull the cover of the CCE 4000 upwards. In front of you, you see the sorting area of the CCE 4000. Remove the coin
boxes from the brackets and blow the dust around the transport brush downwards through the pipes of the individual coins. In
addition, you can also work with compressed air spray from below through the pipes against the transport brush in order to
remove static dust on the sensors. After cleaning, insert the cover of the CCE 4000 onto the device and place the safety-lock
switch on the back of the closed lock symbol and insert the coin boxes back into the device.
Please use only non-flammable compressed air sprays when cleaning the counting machine.
Error code
Error code
Infrared error Sensor 1 (1 Cent)
ERR 1
Infrared error Sensor 2 (2 Cent)
ERR 2
Infrared error Sensor 3 (5 Cent)
ERR 3
Infrared error Sensor 4 (10 Cent)
ERR 4
Infrared error Sensor 5 (20 Cent)
ERR 5
Infrared error Sensor 6 (50 Cent)
ERR 6
Infrared error Sensor 7 (1,00 Euro)
ERR 7
Infrared error Sensor 8 (2,00 Euro)
ERR 8
Infrared error Hopper Sensor
ERR 9
After the machine has been opened, it has
CLOSE
been forgotten to push the safety-lock slider
HOPPER
back into the closed position.
Cause of error
Solution
Clean the corresponding IR sensor, if the fault should not
be remedied, the corresponding IR emitter must be
replaced by the service.
Place the Safety-Lock slider in the closed position.

Werbung