Troubleshooting
8.2
Error codes and flashing sequences
Flashing code
Short orange flashes
1x long green
light
1x long red flash
Short orange flashes
(every 10 seconds)
Alternating long and short
orange flashing
1x orange and 1x green
flash (after connecting the
power supply)
Meaning
Radio transmission / at-
tempting to transmit /
data transmission
Transmission confirmed
Transmission failed
or duty cycle limit
reached
Pairing mode active (pair-
ing with the Access Point
or Home Control Unit)
Device software updating
(OTAU)
Test display
Solution
Wait until the transmis-
sion is completed.
You can continue opera-
tion.
Please try again
(see
„8.1 Duty cycle" on page
19).
Enter the last four digits of
the device serial number
to confirm
(see „6.1 Pair-
ing" on page
16).
Wait until the update is
completed.
You can continue once
the test display has
stopped.