MULTIMETER
EPM-06
/ 06C / 06CS
Below measurement
and application
EPM-06/06C/06CS.
1)Phase currents
(IL). Neutral
ÉPM-06C/06CS);
Phase-Phase and Phase-Neutral voltages canbemeasu
Existence at live phases can be observed by Ll L2 1.3LEDson the device
3 Min and max values for measured
wth only one button
4)Max
demand
values for measured
time can
be defined
in "dE t' • menu
4 digit password
can be defined
changeof settingsbyunauthorized person
6)Currcnt
transformer
ratio is programmable
Current transformer ratio can be programmed in term of "turn number"
between 1
20 (far CT-25 adapted
Voltage transformer ratio is programmable (0 1
7) A user defined measurement range is used for monitoring the voltages
and currents; and Outl & Out2 cutputs are used tor warning the user and
disconnecting the device in case of exceeding the limits of measurement
range
8) In case af using the device far measuring the current values of motors etc
Start delay (AI_Jt0rSt) function can be used for preventing the equipment
against the Improper tripping, which is because of the demurrage current
9) When a failure has occured
device with saving its position (Latched), even it the failure conditions are
romovcd
7th, 8th and 9th subjects are valid for EPM-06C/06CS.
Using the Buttons:
Some buttons and button groups are used for the below special function
when device is in the measurement mode (Without se ecting a menu)
Switching between the phase phase voltages in fourth display
used tor changing
the menu settings and parameters
mode
used for monitoring min / max currents and voltages or max demand
values Switching to the programming made it it pressed for 3 sec In
programming mode; it is used for switching to the menu and saving
changes lor the parameters
Switchinq betweenneutral c urrentand phasecurrentinmeasurement
mode Switching to the previous menu and escaping the programming
menu without saving the changes
If the Latch function is turned on (EPM 06C/06CS); output will be
released when current(s) of system is exceed the defined values
When the system's
current
doesn't
react
Output can be trigged
Commissioning
and menu setting
gorEPM-
06/06C/06CS)
nergize the device after imp ementing the connections respected to the
user
manual
Enter the proper
menu settings
aoolications
Current Transformer Ratio Setup:
ErR
n this menu, current
(This menu is not available in the devices which are adapted
With CT-25 )
Note: If the current transformer is not used between the system
and device,
current
Example: If a current transformer which has a ratio of 30/5A is
used between the system and device;
Current
transformer
Press SET button tor 3 sec (trA Fo menu is displayed)
SET
Press SET button; trA Fa Ctr menu is displayed (In CT 25 adapted
devices, trA Fo trn is displayed instead )
Not: trA FOutr or Can nEC tio n menu can be displayed hy scrolling
thc UP/DOWN buttons )
Press SETbutton Blinking tha first digit ot displayed value appears
("trA Fo utr- or •Con nEC tio n" menu can be
SET
programmed similarly )
Enter the blinking digit value by scrolling
LIP/OOWN
buttons
digits by using SÜ button, use rSC button
to go to previous digit After you entered
the lastdigit ressSEI button,"trA Fo Ctr'
isdisplayed
P
Data i sentered
activated yet
Or activating the new data
please follow the beltfu steps)
Press ESC button one by one until
"SAIJ E SEt YES" is displayed
Press SET button
When
SEt YES"is displayed(If„you
press ESC button
choose no"
option instead Of'YES' then new
data
will
be
cancelled
previous value will be activated)
programming
the Turn Number:
ErR
This menu is available for CT 25 adapted devices IJser defines the
turn number, which is the number of how many tour the current
cable has rounded
bet,veen 1-20 Greater the number ot turn means greater the
sensivity
Err,
120
60
30
240200171
can be implemented
current (IN). frequency
currents and voltages can be monitored
current
can be monitored,
from pin menu in order to prevent
(1
2000)
devices)
4000)
use the Lalch function,
in order to keep the
In programming
turns back to normal values then output
by the "ESC" button
in order to correct
measurements
transformer
ratio is set between
transformer
ratio is entered
as '1
ratio
is
entered
as
—
Switch
to the
ather
but i snot
I-rR
"SAIJ
E
and
P q P
into the CT-25
Numbers
can be selected
50
33120
109100923
57
0
750705666631
with
Voltage
n this menu. voltage transformer
and
EPM 06. voltage transformer ratio is entered as '1
Example: If a voltage transformer which has a ratio of 34 5KV/1DOV
LIE,-
is used between the system and device; Voltage transformer ratio
demand
is entered as 345 (34500/100)
the
Selecting
L on
Connection
nEC
Phase-Neutral voltage monitoring can be implemented if the "Star"
connection
Phase-Phase voltage monitoring can be implemented it the "Delta'
connection
NOTE: When the "Delta"
monitoring"
displaying
user Password
In this menu user password is defined and activated
You must define and activate a 4 digit user password for preventing device
settings trum the illegal usage
There
EE
and
1 - 2000
30/5
=
6
CHR
n3E
co
2
Transformer
Ratio:
ratio is set between 0.1 - 4000.0
: Ifthe wltage transformer is not used benveen the system and
the Connection
Type :
can be selected
as Star or Delta in this menu
is se acted
is selected
connection
can not be implemented
function
Of ESC button
Setup:
are 2 sub
menu
in the Pin menu
Activating
the user password
Ihis menu is used tor activating the user passu•ord
Aftert
user password is activated for entering to the menus:
If the
button is pressed for 3
are observed, user password is required
is entered wrong device does not latch
Note:
Factory
default
value ot user password
To activate the user password; in measurement mode
Press SET button tor 3 sec (trA Fo menu is displayed)
Find the "Pin" menu by scrolling UP,'DOWN buttons
Press SET button
(Pin Act II-JAtE is displayed )
Press SET button Blinking the first digit of displayed value appears
Enter the blinking digit value by scrolling
UP,'DOWN
buttons
Switch
to the Other
digitsbyusingSETbutton. u se ESCbutton
to go to previous digit Alter you entered
the last digit press SET button. "Pin Act
OF" is displayed •on" can be selected by
scrolling
UP/OOWN buttons
(Data is
entered
but is not activated
yet
activating the nco,vdata please follow the
below steps)
Press FSC button one bv
one until
"SAUE
SEt
is displayed
Press SET button
When
'SAU E SEI YES" is
displayed
(It you press
ESC button or choose •no' option instead ot •YES" then new data will
he cancelled and previous value will be activated)
Changing
of User Password:
This menu is used for changing thc user password
Note: Factory default value for user password is "0000"
To change the user password: in measurement mode
Press SET button for 3 sec (trA Fo menu is displayed)
Find
the
"Pin"
menu
by scrolling
LJP/DOWN buttons
Press
SET button
(Pin ACt IDA tE is
displayed )
Find the "Pin CHA ngE" menu by scrolling UP/DOWN buttons
is selected,
"neutral
current
even it it is activated
and
Will be disabled
also.
:
, while the instant values
If the user password
is "0000"
Fo
n3E