MULTIMETER
EPM-06
/ 06C / 06CS
INDEX
Precautions for Installation and Safe usage
Frc"t Fanel and Usage Of auttons
General
Information
and Applications
using
the
Transformer Menu (Ctr tm utr / CcnnECtlon)
user Password Settings (Pin Menu)
Activating the user Password (Pin Act Menu)
Changing
the
User Password
(Pin CHO Menu)
Output
Setting
Menu
Current Setting Menu (SP Current Menu)
Highß_ow Current Settings (SP Cur HI, SP Cur Lc Menu)
Hysteresis Settings for High/l_On•Currents (Cur HI Hys, Cur LO HYSMenu)
Delay-on
Time tar High,'Low
Currents
Delay off Time for High'Low currents {HI oFFdEL.
Start and Auto Function (StArt dEL and Auto rSt Menu)
Instant
Trip
Function
(Cur
InS trp
Voltage Setpoint Menu (SP Volt Menu)
High,'Low
Voltage
Settings
(SP CIOL HI. SP OOL Lo Menu)
Hysteresis Settings for High/Low Voltages (LJOL_ H I Hys, UOL Lo Hys Menu)
Delay on Time for High/Low Voltages (HI on dkl_, Lo on dEL Menu)
Delay-ott
Time
for
High/l_ow
Voltages
Menu
High,iLow
Frequency
Settings
(Frq
H;steresis
Settings for High/Low
Frequencies
Delay on / Delay ot! Time tor High/Low Frequencies (Prq on dEL, Frq OFF dEL)
Phase Sequence
(Voltage Sequence
Menu) and Instant Trip (IJOL InS trp Menu) Menu
lhe
Max . Min
Max
Demand Time tor Demand and Max Demand (dE tl Menu)
Communucation
Menu
(RS-485)
Technical Features and Default Factory Settings
Connection
Diagram
Output, SP Current and SP volt menus are available for EPM-06C/06CS;
is available
for EPM-06cs.
PRECAUTIONS
FOR INSTALLATION
In CT-25 (120A) compliant models, only CT-25 current transformer
must
be used.
Other type of CT's have a high risk to damage to device.
Failure to follow those
instructions
- Disconnect
all power before working
- When the device is connected
panel.
- Do not try to clean the device with solvent
- Verify correct terminal
connections
- Electrical
equipment
should be serviced
- Only for rack panel mounting.
- Fuse must be F type and limit value doesn't
NO responsibility
is assured by the manufacturer
for any consequences
arising out of the use of this material.
Ll
L3
o
o
O
13
16
18
19
30
(HI on dELi Lo on dEL Menu)
dELMenu)
Menu)
(HI oFF dEL.
Lo oFF dEL
Menu)
HI. Frq Lo Menu)
(Frq HI HyS, Frq Lo HyS)
Demand
Values
(Reset
Menu)
AND SAFE
USE
will result in death or serious injury
on equipment
to the network,
do not remove the front
or the like.OnIy
clean with dry
when wiring.
only by your component
exceed IA.
or any Of its subsidiaries
10
11
Outl
MULTIMETER
EPM-06CS
A
OLI
Esc
OL3
o
2
10
11
30
29
Phasa LEDs:The LEDs turn on when the voltage value, which is applied
to one Of the current inputs, reach 30 V
First display's k LED (for L1). Measurement
when LED is turned on ie: KA, kV
Display for Ll
4
Second display's k LED (for L2and neutral current). Measurenwnt parameter
is the unit Of kilo when LED is turned on ie, kA, kV
Display for L2 and neutral current.
RS 485 menu
6
Third disp av's k LED (for L3) Measurement
when LED is turned on ie: kA, kV
Display tor L3.
8
Displays network frequency
Display for frequency and coso (torEPM 06C,'06CS).
10
First warning output
Second warning output LED (Out2)
Over
12
13
Low
14
Over current / voltage warning
Low
16
over
Low
seller.
18
Over current / frequency
Low current trequency warning output for frequency (EPM-06C/06CS)
20
LED for max instant currant and voltage
voltages
L LED for min. instant current and voltage. Min. instant currents and
voltages
22
M LED for max demand Max demand values are displayed when this
LED
23
SET
It SET button is pressed for 3 sec. in the measurement
enter into menus This button is used for monitoring
(L) current values and max demand values in measurement
3
24
Downward selection
EPM-06C/06CS
2
IJpward
25
5
EPM 06C/06CS
4
26
ESC button
Escaping
While
6
Over voltage warning LED which is displayed in fourth display
27
28
Low voltage warning LED which is displayed in fourth display
29
29
These LEDs are used tor which phase reters to measurement
in 4th display
Display for monitoring
This LED: indicates
31
voltage values in 4th display
23
Indicates
ndicates
32
k LED for monitored
General
EPM-06/06C,/06CSis designed for measuring the below parameters in a a-Phase
system
Phase current, frequency,
Phase-Neutral)
EPM 06C/06CS:
Device has 2 warning output which named as Outl and Out2 (NO-NarmalVOpen)
Please refer to "Output'
8
27
19
32
31
8
9
When HZ LED is turned on
LED (Outl)
Turned on when the output is activated
Turned on when the output is activated
current
/ voltage
warning
current
/ voltage
warning
currant
/ voltage
warning
current
/ voltage
warning
current
/ voltage
warning
warning Output for frequency
are displayed
when this LED is turned on
are displayed
when this LED is turned on
is turned
on
button
It is used
to enter
into
button
And also switching
selection
button. And also switching
Displaying the neutral current during the measurement
from the menu. And also used for switching
this function
has activated
the phase voltages
Coso when Ll. L2 or L3 activated for monitoring
average
value ot inductive
average value ot capacitive
phase in 4th display
information
neutral current and voltages
menu far the functions Of the relays
16
4
6
O
18
4
25
21
22
parameter is the unit ot kilo
parameter
is the unit Of kilo
output
for
Ll
(EPM-06C/06CS)
Output
for
Ll
(EPM 06C/06CS)
output for L2. (EPM-06C/06CS)
output
for
L2
(EPM 06C/06CS)
output
for
L?
(EPM-06C/06CS)
output
for
L3
(EPM 06C/06CS)
(EPM 06C/06CS)
Max instant currents and
the
menu
and
to save
the
values
mode. ycvacan
the max
Min
mg)de
between the phases for
between
the phases for
mode
off the Latch function
of Wltage
(According
to related phase)
Cosw when Ll-L2
are activated
Cos,p when L2-L3 are activated
(Phase Phase and