2) The product requires the blower to keep inflating, and do not to cut off the
power supply.
3) In case of power failure, please escape through the front door or safety window
or back door.
4) In case of emergency, you can cut through the tent with a knife to escape.
5) It is recommended to choose a flat and clean open ground to use this product.
6) If the tent shakes too much in the wind, please use the windproof ropes and
stakes to fix the tent.
7) After repeated use, the ventilation of the tent may become poor. At this time,
the inner blue filter cotton can be removed or replaced to improve the ventilation.
8) If it is difficult to inflate the tent, zip up the front and back doors, turn on the
Ventilation blower to inflate the tent, and then turn on the Inflation blower to fully
inflate the tent.
1.When the product is finished, it is recommended to dry the tent and put it away.
2.If the product is stored in a humid environment, it is recommended to take it out
to open it in sunny weathers.
3.If the product is torn, please repair it with the accompanying material and tools.
Troubleshooting
problem
Blower does
not work
Lack of tent
pressure
MAINTENANCE
cause
· Voltage mismatch
· No power supply
· The blower switch is not on
· Voltage instability
· The air tube is connected to
a wrong blower
· Both exhaust ports are not
zipped properly
solution
· Voltage need to match
· Turn the power
· Turn on the blower
· Supply a stable voltage
· Connect the air tube to the
inflation blower
· Zip both sides of the exhaust
ports