19'' patch panel surge protector for high speed network
STP
Electrical Characteristics
Network
Nominal line voltage
Max. DC operating voltage
Max. load current
Max. data rate
Max. frequency
Insertion loss
Protection level
Following the test category C3 (IEC61643-21) - Line/Line
Max. shunt capacitance
Impulse current
2 x 10/350µs Test - D1 Category
Line/Line Nominal discharge current
8/20µs Test x 10 - C2 Category
Line/Ground Nominal discharge current
8/20µs Test x 10 - C2 Category
Mechanical Characteristics
Technology
SPD configuration
Connection to Network
Format
Mounting
Housing material
Operating temperature
Protection rating
Failsafe behavior
Disconnection indicator
Spare module(s)
Remote signaling of disconnection
Pin outs
Dimensions
Standards
Standards compliance
Part Number
10Gigabit Ethernet, Cat.6 cabling
Un
5 Vdc
Uc
8 Vdc
IL
1000 mA
10 Gbps
f
250 MHz
< 1 dB
Up
20 V
C
< 25 pF
Iimp
500 A
In L/L
500 A
In L/PE
2000 A
GDT+clamping diode
24 ports de 8 wires
RJ45 shielded female input/output
Rack 19''
Baie 19''
Aluminium
-40/+85°C
IP20
Short-circuit
Transmission interrupt
12-port PCB
no
(1-2)(3-6)(4-5)(7-8)
See diagram
IEC 61643-21 / EN 61643-21 / UL497 B / IEEE
802-3an
581515
CITEL • 2 rue Troyon • 92316 Sèvres Cedex • France • Tel: +33 1 41 23 50 23 • e-mail: contact@citel.fr • www.citel.fr
201910 • CITEL2CP-PL24-CAT6-en • Document Subject To Modifications Without Notice
PL24-CAT6
Surge protector for CAT6
24 ports
19'' patch panel 1 U
100/1000/10Gigabit Ethernet network
compliance
Connectors RJ45 shielded
Bi-directionnel
P: 3-electrode GDT
DBC: Low capacitance diode
DATALINE
loading

Inhaltszusammenfassung für Citel PL Serie

  • Seite 1 IEC 61643-21 / EN 61643-21 / UL497 B / IEEE 802-3an Part Number 581515 CITEL • 2 rue Troyon • 92316 Sèvres Cedex • France • Tel: +33 1 41 23 50 23 • e-mail: contact@citel.fr • www.citel.fr 201910 • CITEL2CP-PL24-CAT6-en • Document Subject To Modifications Without Notice...
  • Seite 2 Technical Data Application example Dimension N150506 External 2000 m max. network INSTALLATION INSTRUCTIONS - NOTICE D'INSTALLATION 6500 ft max. NOTICIA DE INSTALACIÓN - INSTALLATIONSHINWEISE ISTRUZIONI PER L'INSTALLAZIONE -40/+85°C max. -40/+185°F max. INSTRUCOES DE INSTALACAO - MONTÁŽNÍ NÁVOD IP20 - 安装指导书 indoor use only Ethernet surge protector LINE...
  • Seite 3 下使用; - Svodič přepětí se smí používat pouze v souladu se svými technickými parametry a podle těchto www.citel2cp.com - 应根据具体应用和工作电压选择器件(表1) montážních pokynů. www.citel.de - Svodič přepětí musí být vybrán podle aplikace a - 如果信号中断,则模块已失效,应予以更换 www.citel.us napěťové úrovně (tabulka 1). www.citel.com.cn - Je-li signál přerušen, je svodič...

Diese Anleitung auch für:

Pl 12-cat seriePl 24-cat seriePl24-cat6