Herunterladen Diese Seite drucken

Suaoki S200 Bedienungsanleitung Seite 9

200wh

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
• 50Hz/60Hz Frequency Selection
Step 1: Press the power button, DC button and AC button at the same time. The LCD screen
would light up and display the current frequency (50Hz or 60Hz). Release the buttons
and move on to the next step.
Step 2: Long press DC button or AC button to select between 50Hz and 60Hz. The frequency
displayed on LCD would change accordingly.
Step 3: Once the desired frequency is selected, press AC and DC power button at the same time
to confirm the choice. When the setting is done, repeat Step 1 to check the current
frequency.
Note: If DC 12V output port is overloaded or short-circuited, BMS protection may be triggered.
As a result, the product will shut down and cannot be turned on. In this case, you need to charge
the product to activate it.
Trouble-shooting
Error codes
E01
E02
E03
E10
E11
E12
E13
E14
E16
Cause
Over-temperature protec-
tion (System)
Over-voltage protection
(Battery)
Battery damage protection
SOC (state of charge)
protection
Battery low-voltage
protection
Inverter over-current
protection
Inverter over-load protec-
tion
Inverter short-circuit
protection
Charging over-voltage
protection
Check whether the ambient temperature is
higher than 40°C. When the temperature cools
down, the output will be turned on again.
Disconnect the product from power source to
stop charging and restart it.
Contact Suaoki customer service.
Charge the product in time and restart it after
fully charged.
Charge the product in time and restart it after
fully charged.
Check whether the AC output port get
overloaded or short-circuited.
Check whether the AC output get overloaded,
please refer to the 'Product Specifications'
section for overload capacity.
Check whether the AC output port get
overloaded or short circuited.
Check whether the input voltage exceeds the
maximum input voltage.
EN-6
Solution

Werbung

loading