(7) Fault finding

WARNING: Maintenance work shall have to be carried out with the unit switched off, i.e. with mains
plug removed.
Display C
PROBLEM
0101
None
Defrost
None
Full
Alarm 1
Lo t
Alarm 2
Lo T
Alarm 3
LOPt
Alarm 4
Hi T
Alarm 5
Pro1
Alarm 8
Pro2
Alarm 8
Pro3
Alarm 8
Performer: B - user , AST - authorised service technician
Ask your local dealer for spare parts or get in touch with HEYLO service department. We will be
pleased to help you !
CAUSE
After plugging the mains plug,
the version of the software is
displayed
Device in defrosting mode
Condensate tank is full
Defrosting has failed
Ambient temperature below 1
deg. C
Temperature difference too
low
(dew-point not made)
Ambient temperature over 36
deg. C / humidity < 75 per cent
rH
Temp. Vaporiser sensor T1
Temp. Vaporiser sensor T2
Temp. Sensor Room temp. T3
22
Versi
SOLUTION
on
The display goes off after
approx. 4 s.
Device starts automatically
after max. 8 min.
B
Empty tank and place it
B
Pull mains plug and after 10 s
switch on again
B
Place device in room with > 10
deg. C for 30 s.
Alarm is reset automatically.
B
Device starts after 210 s
automatically; after three
failures, press button 3+4
(press for 10 s) to reset.
B
Automatic start, if temperature
< 35 deg. C
AST
Contact HEYLO service
department
AST
Contact HEYLO service
department
AST
Contact HEYLO service
department
EN