Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Elements And Connections - EuroLite DMX SPLIT 8X RDM Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. OPERATING ELEMENTS AND CONNECTIONS

8
9
10
1
DMX512 outputs 1 - 3
Rear DMX outputs 1 to 3 to connect further DMX chains.
2
Status indicators DC and SIGN
DC (red) = port is powered, SIGN (green) = DMX signal is present.
3
DMX512 feed-through output
Direct DMX output for connecting additional DMX devices or DMX splitters within the same
DMX chain as the DMX input. This output is only active when the TERM switch is not pressed.
4
TERM selector switch
• Switch pressed: The DMX line of the DMX input is terminated by a resistor. The feed-through
DMX output is disabled.
Switch not pressed: The feed-through DMX output is active.
5
RDM FILTER selector switch
• Switch pressed: The filter is active. All RDM data is filtered out of the DMX line.
Switch not pressed: The filter is disabled. RDM information will be passed bidirectionally
between all devices connected.
6
QuickDMX input
DMX signal input (5-pin XLR) for connecting a wireless QuickDMX receiver. The connector
provides the required 5 V operating voltage.
7
Power switch
Turns the unit on and off.
8
Power input
Used to plug the supplied power cord in.
9
Fuse holder
Only replace the fuse when the device is disconnected from mains. Only use fuses of the same
rating and power. The correct value is specified on the device.
10
DMX512 input
For connecting the DMX control signal.
11
DMX512 outputs 4 - 8
Rear DMX outputs 4 to 8 to connect further DMX chains.
12
Status indicators DC and SIGN
DC (red) = port is powered, SIGN (green) = DMX signal is present.
1
2
3
4
5
11
12
13/16
6
7
00094261.DOCX, Version 1.0