Rotation of the nozzle
6/ INCIDENTS DURING OPERATION
Always check that you are actually using gas-phase propane and not propane in the liquid phase.
PROBLEMS
The RAFALE does
not ignite.
The sound of gas
cannot be heard
when the trigger is
fully depressed.
The sound of the
gas can be heard
when the trigger is
fully depressed.
7/ MAINTENANCE
Always ensure that the equipment is protected against impact and protect the hose from extreme
stress (flames, trolley or vehicle wheels etc.).
Change the hose as soon as it starts to deteriorate or after three years use (see technical data sheet
for conditions for replacement). The date shown on the hose relates to its date of manufacture.
Clean the exterior of the equipment with a damp cloth in order to keep it clean. After removing the
hose (quick connector) blow through both sides of the grille as well as the venturi (at the gun inlet) to
expel all foreign matter. Clean the venturi with a damp cloth introduced through the rear of the
equipment.
Removing and refitting the burner
- Purge the hose, disconnect the equipment.
- Fully unscrew the knurled screw holding the burner; withdraw the burner.
35271b-EN-FR-NL-DE-FI-PL
- Disconnect the equipment.
- Slightly unscrew the knurled screw which holds the burner.
- Align the nozzle at the desired angle, re-tighten the screw.
CAUSES
The cylinder valve is not open.
The cylinder is empty.
The regulator gauge safety
device is in the closed position.
The gas cylinder temperature is
too low (frosting).
The gas cylinder valve flow
limiter has been triggered
(France)
Disconnect the equipment and
check that a good spark is
produced in the centre of the
burner. There is no spark
produced.
REMEDIES
Open the valve by turning it in the anti-
clockwise direction.
Replace it with a full cylinder.
Depress the regulator gauge operating
button.
Use another cylinder or a larger cylinder.
Use the EXPRESS coupler Item. 18970 to
connect 2 cylinders.
Close the cylinder valve and open it slowly.
Check the piezo ignition unit.
5