Current limiting protector
Protector cuts out
repeatedly
Air tank pressure drops
when compressor shuts
off
Excessive moisture in
Discharge air
Compressor runs
continuously
Air output lower than
normal
LOW voltage
Lack of proper ventilation/
room temperature too high
Wrong gauge wire or length
of extension cord
Loose connections (fitting,
tubing, etc.)
Loose drain valve
Check valve leaking
Excessive water in air tanks
High humidity
Defective pressure switch
Excessive air usage
Piston ring are worn
Broken inlet valves
Connections leaking
Check with voltmeter
Move compressor to well- ventilated
area
Check for proper gauge wire and
cord length
Check all connection with soap and
water solution and tighten
Tighten drain valve
Take compressor to service center
DANGER
Do not disassemble check valve,
tank drain valves or safety relief
valve with air in tank- bleed tanks.
Drain tanks
Move to area of less humidity; use
air-line filter
Take compressor to service center
Take compressor to service center
Decrease air usage; compressor not
Large enough for tools requirement
Replace piston rings; Air intel filter
is blocked, call customer service for
assistance
Tack compressor to service center
Tighten connections