PROBLEM
Compressor will not run
Motor hums but cannot
run or runs slowly
|
30
Air Compressor 50Liter
CAUSE
Loss of power or overheating
NO electrical power
Blown shop/house fuse
Shop/house breaker open
Current limiting protector
open
Pressure switch bad
Tank is full of air
Low voltage
Wrong gauge wire or length
of extension cord
Shorted or open motor
winding
Defective check valve or
unloader
POSSIBLE SOLUTION
Check for proper use of extension
cord
Check to be sure unit is plugged in
Check fuse/ breaker
Replace shop/house blow fuse
Reset shop/house breaker, deter-
mine why problem happened
Motor will restart when cool
Compressor will tum on when tank
Pressure drops to cut-in pressure
Check with voltmeter
Check for proper gauge wire and
cord length
Take compressor to service center
Take compressor to service center