Use the +/- buttons to adjust the values, by pressing „OK" you reach the next value, by pressing
„M" you can exit the switching point.
For example: If you set 6:00 to 6:30, 0% to 100%, then the light will light up from 6:00 and in 30
minutes will go up to 100% brightness. This means that the brightness will increase about 3.33 %
every minute. At 6:30, 100% are reached.
If you set 6:00 to 8:00, 1% to 100% (or 100% to 1%), the brightness will increase or decrease by
0.83% every minute.
If the light shall not get constantly brighter, set 6:00 to 18:00, 70% to 70%. Then it will light up at
70% for 12 hours.
If you set 21:00 to 5:00, 0% to 0%, then the light is off from 21:00 to 5:00 the next morning.
If the light should work as a moonlight at night, you should select maximum 1% during the dark
phase. The zooxanthellae of corals as well as the plants should not be encouraged for photosynthesis
at night.
After all programs are set, press M to exit. All programs are saved now. If the dimmer is on, only
the time is displayed.
Hints:
1. Each setting time refers to the last setting, e. g. if the first setting is 06:00 to 07:00, then the
next setting can only start at 07:00. No time before 07:00 can be set.
2. The dimmer saves the settings, even if it is unplugged. If the dimmer is switched on again,
works with the last saved settings.
After disconnecting the power supply, it takes about one minute for the controller to turn on the
connected light.
5.
Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid. Proof
of Purchase is required by presentation of the original invoice or receipt indicating the dealer's name,
the model number and date of purchase. This warranty may not apply if any model or production
number has been altered, deleted or removed, unauthorised persons or organisations have executed
repairs, modifications or alterations, or damage is caused by accident, misuse or neglect. Please note
that the product is not defective under the terms of this Warranty where the product, or any of its
component parts, was not originally designed and / or manufactured for the market in which it is
used. These statements do not affect your statutory rights as a customer.