9. Faults
Warning:
- Disconnect the power supply before carrying out work on the unit.
Table 1: Faults
Signalling
LED on anti-static bar
does not light up
LED on the anti-static
bar flashes green
LED on anti-static bar
lights up red
LED on anti-static bar
lights up green
LED on the anti-static
bar flashes red
10. Repairs
Warning:
- Disconnect the power supply before carrying out work on the unit.
- Electrical installation and repairs must be carried out by a skilled electrical engineer
according to the applicable national and local regulations.
Performax Easy and Performax Easy Speed parts cannot be repaired. To order parts, see the
spares list.
Please contact SIMCO (Nederland) B.V. or your regional agent in the event of any problems.
Request an RMA number for any returns by sending an e-mail to service@simco-ion.nl.
Package the Performax Easy properly and state clearly the reason it is being returned.
Performax Easy/Performax Easy Speed_UM_9752152130_NL_D_GB_F_V3_0
Problem
No high voltage at
emitters
No high voltage at
emitters
Anti-static bar
overloaded
No/poor ionisation,
despite high voltage
at the emitters
High voltage at the
emitters, no HV OK
signal
Cause
No supply voltage
Wiring fault
No remote on/off signal
Wiring fault
Anti-static bar fouled
Anti-static bar fitted
too close to conductive
machine parts
Anti-static bar fouled
Emitters are damaged
Anti-static bar incorrectly
positioned
Emitters are covered
HV OK overloaded
Wiring fault
Solution
Switch on supply
voltage
Locate fault and
remedy, see 5.3
Connect/activate
remote on/off
Locate fault and
remedy, see 5.3
Clean anti-static bar
Move anti-static bar
Clean anti-static bar
Replace the anti-static
bar
Reposition the anti-
static bar, see 5.2
Remove the cover
Load HV OK differently
Locate fault and
remedy, see 5.3
37
GB