8.
Faults and remedies
Type of fault
indicator lights on the
smartDRAFT™ Cooler
are not on
smartDRAFT™ Tap does
not fit on the
smartDRAFT™ Keg
smartDRAFT™ Tap is not
working
too much foam
drink is too warm
compressor does not work compressor is not switched on
cooling fins in the
smartDRAFT™ Cooler are
covered in ice
advert display on the
unit's rear – side (optional) the bottom right of the unit
does not light up
20
Possible causes
plug not connected
power supply unit defective
indicator lights defective
the front part of the smartDRAFT™ Tap
does not lie in the cut-out in the
top ring of the smartDRAFT™ Keg
the smartDRAFT™ Tap was not attached
completely withdrawn
smartDRAFT™ Tap is not attached
properly
smartDRAFT™ Keg has not been
pre-cooled
dispensing temp. not yet reached
doors of smartDRAFT™ Cooler are
not properly closed
smartDRAFT™ Keg has not been
pre-cooled
cooling fan motor dirty or defective
ventilation grille is covered
unit placed too close to a wall
refrigeration circuit leaks or the
compressor is defective
or is defective
doors of smartDRAFT™ Cooler are
not properly closed
smartDRAFT™ Cooler has been
operated without a Keg
check that the toggle switch on
is switched on
lighting defective
Remedy
put the plug in
inform service technician
pay attention to status indicator
attach the smartDRAFT™ Tap so that
the front part fits in the cut-out
of the top ring
completely withdraw the smartDRAFT™ Tap
and attach it on the Keg
please refer to instruction on
page 9
pre-cool smartDRAFT™ Keg and
pay attention to status indicator.
(yellow blinking light = dispensing
temp. not yet reached / yellow light
permanent = dispensing temp of
8°C reached)
wait until status indicator stops
blinking
close doors until you hear locking
button click into place
pre-cool smartDRAFT™ Keg and,
pay attention to status indicator.
inform service technician
uncover grille
ensure sufficient distance
inform service technician
inform service technician
remove the plug from the power
supply, allow the fins to defrost.
Mop up any moisture with a soft
cloth. Always close the doors until
you hear the locking button click
into place.
remove the plug from the power
supply, allow the fins to defrost.
Mop up any moisture with a soft
cloth. smartDRAFT™ Cooler
may only be operated with a
smartDRAFT™ Keg
turn the display on at the switch
inform service technician