Herunterladen Diese Seite drucken

Thitronik G.A.S.-plug all in one Bedienungsanleitung Seite 3

Mobiler gaswarner für propan, butan und ko-/narkosegase
Vorschau ausblenden Andere Handbücher für G.A.S.-plug all in one:
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
G.A.S.-plug "all-in-one" is an effective, compact and versatile mobile gas detector
for propane, butane and anaesthetic gases, which reliably alarms in the event of an
anaesthetic gas attack or gas leak.
The dynamic temperature adjustment and continuous sensor self-test guarantee
perfect functioning under a wide range of climatic conditions.
Placement:
Plug the G.A.S.-plug "all in one" into a cigarette lighter socket with continuous current.
Ensure that the G.A.S.-plug "all in one" is not exposed to the air flow from heating vents
and keep a sufficient distance from lead-acid batteries. G.A.S.-plug "all-in-one" is not
suitable for use in wet rooms.
Minimum distances:
Heater outlets
Lead-acid batteries
Commissioning:
-  Plug the G.A.S.-plug "all in one" into the cigarette lighter socket.
- The operating indicator (A) lights up yellow continuously (this can take up to 20
minutes during initial commissioning) and then changes to green.
- After approx. four minutes, the power indicator flashes green and the G.A.S.-plug "all
in one" is ready for use.
Sensor error:
If a sensor error is detected during the self-test or under operation, the device will
indicate this by a yellow continuously lit operating indicator. In addition, a continuous
beep sounds until the device is switched off. If this error occurs, please contact the
support.
Alarm sequence:
If the sensor alarm threshold is exceeded, an alarm is immediately triggered: The oper-
ating indicator (A) starts to flash red and the piezo emits the alarm signal at full volume
for 30 seconds. The operating indicator continues to flash for another 30 seconds (60
seconds in total).
If the threshold value is still exceeded after 60 seconds, the scenario starts again.
This is repeated until the value falls below the threshold.
To stop the alarm, remove the plug from the cigarette lighter socket. Remember re-in-
sert the plug in after the vehicle has been sufficiently ventilated.
Scope of supply: G.A.S.-plug "all in one", warning stickers, instructions
English
1.5m
1.0 m
loading

Diese Anleitung auch für:

100042