Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
E N
5.6.1.
Hose connection.
Proceed as follows:
1. Position the O-rings (Fig. 30, Fig. 31, # 3) on the rubber holder (Fig. 30, Fig. 31, # 4).
2. Screw the two rubber holders in (Fig. 30, Fig. 31, # 4) on the inlet and outlet side of the pump.
3. Apply some turns of the supplied teflon around the rubber holders (hydraulic parts) to ensure the pipe is sealed (hydraulic parts) onto the rubber holder.
4. Connect the inlet pipe (hydraulic part) to the IN rubber holder (Fig. 10) and the outlet pipe to the OUT rubber holder (Fig. 10). Fix the pipes (hydraulic part)
with clips.
5. Screw the pre-filter transparent cover firmly in (Fig. 30, Fig. 31, # 2b), if fitted, checking that the O-ring (Fig. 30, Fig. 31, # 2a) is intact and correctly located
in its housing.
Check the hydraulic pipe is as short as possible to minimize the decrease in flowrate. Avoid any deformation or occlusion in the hydraulic pipes because they
might affect the product operation.
Support the inlet and outlet pipes (hydraulic parts) of the product in order to minimize the load on it.
5.6.2.
Pre-filter installation (if absent).
See Fig. 25..
5.6.3.
Priming.
To make priming the product easier please follow the procedure shown in Fig. 26.
Slowly fill the product with clean water from the inlet pipe, checking the outlet pipe fills with water too (Fig. 26, OUT). Switch the product on only when all the
hydraulic parts are filled with water, inserting the plug into the socket; the product shall bleed any air it might still contain and start operation.
5.7. Reinstallation and reuse.
Clean the product and the moving parts accurately before stopping the product for a while, such as, for instance, during the winter months. Do not lubricate
and/or use detergents and chemical cleaning products.
If there is the risk of freezing, the product must be carefully emptied from the liquids in its hydraulic circuit. It is advisable to empty all the hydraulic parts.
Remove the cap to empty the product (Fig. 27), when included.
5.8. Demolition and disposal.
Collecting recyclable material, both those used for packaging (cardboard, nylon, etc.) and those replaced during maintenance is recommended. Suitable
collection of waste material for recycling, processing and environmentally compatible disposal contributes in avoiding possible negative effects on the
environment and health and promotes the reuse and/or recycling of product materials.
Illicit product disposal by the user may be punishable by current international and/or national laws.
5.8.1.
Electric/electronic waste disposal.
EU directive 2002/96/EC classifies this product as an electrical or electronic tool. The barred bin symbol on the equipment or packaging indicates that
the product must be separated from other waste at the end of its working life. Therefore, the user must take equipment to electronic and electro-
technical waste collection centres at the end of its working life or return it to the dealer when purchasing similar new equipment, on a one to one
basis. Suitable collection of decommissioned equipment for recycling, processing and environmentally compatible disposal contributes in avoiding
possible negative effects on the environment and health and promote the reuse and/or recycling of device materials. Illicit product disposal by the user
may be punishable by current national laws.

6. Operations and use.

Do not use glue, sealant or other chemical products on threads or other product parts.
To disconnect the product from the power mains, remove the power plug from the power outlet without pulling on the power cord.
6.1. Operating description.
The product you purchase is designed to move water in swimming pool. The rotor turns and transfers water from the inlet to the outlet.
6.2. Application range.
The product cannot be used to purify water for human consumption.
The product cannot be used to purify liquids other than fresh water.
The product was designed and constructed to operate in above-ground fresh swimming pool, located outdoors.
This powerful and reliable product can be used in swimming pool, together with a filter, for water treatment.
6.3. Use.
Cutting and/or altering the power cord is strictly prohibited.
The product cannot be used to purify water for human consumption.
The product cannot be used to purify liquids other than fresh water.
The product cannot be used for medical/therapeutic purposes,
Dry operations are prohibited.
6.4. Operating limits and environmental limits.
Maximum water temperature: 35 [°C].
Minimum water temperature: 4 [°C].
6.5. Safety devices and signalling.
The product is equipped with a thermal protector. Following any thermal protector operation, check the causes that originated the product's malfunction. For
this purpose, please consult the "Troubleshooting" section.
The product shall go back to normal operating conditions after it has cooled down (about 2÷3 hours) and/or the caused that triggered the thermal protector have
been eliminated.
6.5.1.
Power plug with residual current device (RCD, when included).
Before turning on the product, always press the RESET button. Check power plug with residual current device operations by pressing the TEST button (T).
Do not attempt to repair or open the power plug with residual current device; in the event of fault, replace the entire power plug with residual current device
with the power cord.
The power plug with residual current device does not replace mandatory electrical safety components: the electrical system must meet current international
and/or national regulations. If necessary, contact specialised technicians.
The power plug with residual current device is an additional electrical safety component able to cut off a circuit in the event of fault. In order for it to work, it
must:
 always be in the vertical position,
 always be clean and free of dust or water,
 be connected to a perfectly efficient ground line,
 check residual current device operations before turning on the product (see below).
6.5.2.
Checking residual current device operations.
Plug the power plug with residual current device into the power outlet:
1. press the RESET button to allow the product to be turned on: the light turns red.
2. press the TEST (T) button to test residual current device operations: the light turns off and the residual current device cuts off electrical power, therefore the
product cannot be turned on unless the RESET button is pressed again.
Nome file:
7500029 - ISTRUZIONI POMPE SERIE SP E PP
File name:
17-40
Rev. 0 06/10/2011

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für SCHOTT PP4000

Inhaltsverzeichnis