PROBLEM
Current limiting protector
Protector cuts out repeatedly
Air tank pressure drops
when compressor shuts off
Excessive moisture in
Discharge air
Compressor runs continuously
Air output lower than normal
CAUSE
LOW voltage
Lack of proper ventilation/
room temperature too
high
Wrong gauge wire or
length of extension cord
Loose connections (fitting
tubing, etc.)
Loose drain valve
Check valve leaking
Excessive water in air
tanks
High humidity
Defective pressure switch
Excessive air usage
Piston ring are worn
Broken inlet valves
Connections leaking
POSSIBLE SOLUTION
Check with voltmeter
Move compressor to well- ventilated
area
Check for proper gauge wire and
cord length
Check all connection with soap and
water solution and tighten
Tighten drain valve
Take compressor to service center
DANGER
Do not disassemble check valve, tank
drain valves or safety relief valve with
air in tank- bleed tanks.
Drain tanks
Move to area of less humidity; use
air-line filter
Take compressor to service center
Take compressor to service center
Decrease air usage; compressor not
Large enough for tools requirement
Replace piston rings; Air intel filter
is blocked, call customer service for
assistance
Tack compressor to service center
Tighten connections