by compressed air.
NOTE
Condensate is a polluting material and should be disposed of in
compliance with local regulations.
1) If drain valves are clogged, release all air pressure, remove and clean
valves, then reinstall.
DANGER!
Unplug the air compressor and release all air from the tanks before
servicing. Failure to depressurize tanks before attempting to remove
valve cause serious personal injury.
Rotate drain valves clockwise until tightly closed.
CHECKING THE SAFETY VALVE
WARNING!
Do not attempt to tamper with the safety valve.
Anything loosened from this device could fly up and hit you. Failure to
heed this warning could result death or serious personal injury.
The safety valve will automatically release air if the air tank pressure
exceeds the preset maximum. The valve should be checked before
each day of use by pulling the ring by hand.
1) Turn the air compressor on and allow the tanks to fill. The compressor
will shut off when the pressure reaches the preset maximum.
2) Turn the air compressor off.
3) Pull the ring on the safety valve to release air for three to five seconds.
4) The ring pin must be pushed back into position to stop the flow so air
at high pressure.
WARNING!
If air leaks after the ring has been released, or if the valve is stuck and
cannot be actuated by the ring, do not use the air compressor until the
26
Air Compressor 50 Liter