Summary:
The function of the individual DIL switches in switch bank
SW4 is shown in the following table:
Operating modes
Time control, standard mode
Time control, transparent mode
Code control
Time control mode (S2 = "OFF"):
Switching time
5 seconds
15 seconds
30 seconds
120 seconds
Code control mode (S2 = "ON"):
Control Port
Port A
Port B
Port C
Subject to error and alteration
RS232 Universal Serial T-Switch
S1
S2
Dump Output
off
off
Port A
ON
off
Port B
X
ON
Port C
All ports
Timeout
S5
S6
0 milliseconds
off
off
30 milliseconds
ON
off
90 milliseconds
off
ON
500 milliseconds
ON
ON
S5
S6
S7
S8
ON
X
X
no function
X
ON
X
no function
X
X
ON
no function
S3
S4
off
off
ON
off
off
ON
ON
ON
S7
S8
off
off
ON
off
off
ON
ON
ON