Guideline for Electrification:
> PLEASE NOTE:
Electrical connections are reserved to authorized
electricians!
> Grace is designe das a „stationary furniture", for which
the subsequent electrification must be scheduled.
If the styling station will be used mobile, the
„Electro technical guidelines for portable furnitures"
must be followed. In this case, the executing
electrician is responsible!
> The styling station must be connected to the
electrical wall outlet or floor outlet by a qualified
electrician according to this mounting instruction.
> Mirror lighting (option) with centrically customer's
switch.
-
With a connection cable protected with 13A, max.
5 styling stations á 2,5A are possible to switch per circuit.
-
If several styling stations are to be switched together, a
power-on limiter can be installed into the customer's
electrical installation by the qualified electrician.
> Electrification variants for plug sockets:
Plug sockets EU: double cover + 2 sockets
Plug sockets GB: double cover + 1 socket + 1 lid
> 2 sockets with 1 shared connection cable not
allowed due to GB rules!
> no internal fuse! Electrical connection and fuse
must be made on-site due to GB technical
regulations!
> The styling station can be ordered with:
- 2 double (GB: single) plug sockets underneath corpus or
- 2 double (GB: single) plug sockets inside corpus
(corpus front with flaps) or
- double (GB: single) plug socket in vertical cable
ducts (1x L/H, 1x R/H or both sides) or
- without sockets.
> Floor junction variants:
Floor cable outlet:
Cables protrude from the floor, are led through the cable
duct into the corpus and connected there in a connection
box to the connection cable of the power adapter of the
lighting (option) and the connection cables of the sockets.
Floor connection box with lid (waterproof):
The connection cable of the power adapter of the
lighting (option) as well as the connection cables of the
double plug sockets are led through the cable duct or
optionally through the vertical plastic cable management
(accessory) to the floor connection box where it is
connected to the floor connection cables.
> Fuse protection of the electricity network:
Each double (GB: single) plug socket must not be fused
with more than 13A. We recommend to secure the
circuits in the salon by means of a RCD (residual current
operated device).
MO Grace Doppelplatz gegenüber
GB
> Styling station without plug sockets, with lighting:
- Only 1 connection required for mirror lighting with
centrally customer's switch.
> Styling station without plug sockets, without lighting:
- no electrical connection required.
Performance data:
> Power input of mirror lighting (power adapter): 60 W / 2,5A