Fixed colour: Selection of a fixed colour among twelve possibilities.
COLOUR Nº
1
2
3
4
5
6
Automatic sequence of colours: Selection of eight colour sequence programmes. Each programme is defined by the lighting time of
each colour and the transition time from one colour to another according to the following table:
SEQUENCE
1
Red
Green
2
Cyan
Magenta
3
Green
Esmerald
green
4
Red
Orange
5
Red
6
Red
Orange
7
Pale
Magenta
violet
8
Red
Green
3. SAFETY WARNINGS:
• The persons who are in charge of assembly should have the required qualifications for this type of work.
• Avoid making contact with the electric voltage.
• Comply with the current standards regarding accident prevention.
• In this regard, the IEC 364-7-702 standards must be observed. WIRING IN BUILDINGS. SPECIAL WIRING. SWIMMING POOLS.
• Any operation related to the maintenance or replacement of parts should be performed with the floodlamp disconnected from
the electric power system.
• This projector is designed TO OPERATE ONLY WITH A SAFETY TRANSFORMER.
• The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric components
which have been inserted or handled at locations other than its own premises.
• The luminaire should be fitted in such a way that it is not possible to stare at it from closer than: LumiPlus V2 = 2.50 m, Mini V2
= 2.00 m, LumiPlus V1, Design and Rapid => 1.10 m. The Mini V3 and Micro V2 are not subject to this standard.
• PAR56, Rapid, Design and Mini V3 projectors: If the cable or wiring of these luminaires becomes damaged, it may only be repla-
ced by the manufacturer or one of its service engineers, or a person with a similar qualification, in order to avoid any accidents.
• Slim, Mini V2 and Micro V2 projectors: The power cable and wiring on these luminaires cannot be replaced; if damaged, the
luminaire must be destroyed. However, a qualified service engineer may make an underwater splice as a repair.
• Rapid, Design, Mini V3, Slim, Mini V2 and Micro V2 projectors: The light source of these luminaires is not replaceable; when the
light source reaches the end of its service life, the whole of the luminaire must be replaced.
• PAR56 projectors: The light source of these luminaires may only be replaced by the manufacturer, one of its service engineers
or a person with a similar qualification.
• The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2 m is not expected".
• For operation only with SAFETY ISOLATING transformer.
COLOUR
Red
Green
Blue
Yellow
Cyan
Magenta
ORDER OF COLOURS
Blue
Yellow
Cyan
Sky-blue
Green Orange
Pink
Blue
Pink
Green
Cyan
Cyan
Yellow
Blue
Yellow
Blue
Pink
White
Yellow
Cyan
Cyan
Magenta
Pale
violet
4
COLOUR Nº
COLOUR
7
Pale violet
8
Sky-blue
9
Orange
10
Pink
11
Emerald green
12
White
Magenta
Sky-blue
Orange
Pink
Esmerald
Whi-
green
te