Fehlersuche und Service Programmablauf Accessories WIKA Global Es gelten unsere aktuellen Verkaufs- und Lieferbedingungen, siehe unter www.wika.de/download WIKA Alexander Wiegand GmbH & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg / Germany Phone (+49) 93 72/132-0 (+49) 93 72/132-406 E-Mail info@wika.de www.wika.de...
If questions remain regarding a specific application, you can obtain further information (data sheets, instructions, etc.) via our Internet address (www.wika.de / www.wika.com / download) or contact WIKA for additional technical support (see section 8, service).
TSD-10 2. Safety Instructions Prior to installing, starting and operating a temperature switch the user must ensure that the appropriate instrument has been selected with regard to scale range and performance and that the wetted parts material are compatible with the media being Caution measured.
TSD-10 3. Installation / Montage (Dimensions in mm / Abmessungen in mm) Temperature switch / Temperaturschalter Connector, Steckverbinder, M 12 Temperature probe / Temperaturfühler Pin assignment Anschlussbelegung...
Seite 6
Connecting adapter Verbindungsadapter Compression fitting Klemmverschraubung G ½ G ½ B G ½ B TSD-10 with cable and probe / TSD-10 mit Anschlusskabel und Fühler Cable for probe Anschlusskabel für Fühler fixed connection feste Verschraubung Compression fitting Klemmverschraubung G ½ B G ½...
TSD-10 4. Technical data Specifications Model TSD-10 Temperature probe Measuring element Pt1000 / DIN EN 60 751 / class B Measuring range -50 ... +150 °C, -58 ... +302 °F Response time = 6 s / T = 25 s Accuracy ±...
TSD-10 Key functions Functions Display unit Go forward in the menu Setting of a higher parameter value Go back in the menu Setting of a lower parameter value Selection of a parameter value / menu item Acknoweldgement of a parameter value / menu item...
TSD-10 Display mode Programming mode In the display mode the set parameter values are In the programming mode the parameters are displayed. changed and permanently stored. 89,7 89,7 keep pressed ProG disp (after 3 sec. automatically) (after 3 sec. automatically)
TSD-10 Functions / Funktionen Hysteresis function ϑ / °C If the system temperature is fluctuating around a nominal value, the hysteresis can keep the status of the switching outputs stable. When the system temperature is rising, the output switches when it reaches the respective set point (SP);...
TSD-10 Delay times (0.00 to 9.99 s): This allows unwanted temperature peaks of short duration or high frequency to be filtered out. The ϑ / °C temperature must be outside the set range for at least this time before the switch will operate. The switching...
TSD-10 Parameter Factory setting Setting range Switch 1 Upper switch point Upper limit of range Measuring range (input as temperature value) rSPI Lower switch point Upper limit of range -10% Measuring range (input as temperature value) Cont Switch type Normally open...
Seite 18
TSD-10 Parameter Factory setting Setting range Options Password 0000 (= no password) 0000 ... 9999 Unit used °C °C °F Display Actual temperature Max. value Min. value Display off Switch point 2 Switch point 1 Actual temperature Analogue output 4-20 mA...
Seite 20
TSD-10 Parameter Werkseinstellung Einstellbereich Optionen Passwort 0000 (= kein Passwort) 0000 ... 9999 Verwendete Einheit °C °C °F Displayanzeige Aktuelle Temperatur Max-Wert Min-Wert Anzeige aus Schaltpunkt 2 Schaltpunkt 1 Aktuelle Temperatur Analogausgang 4-20 mA 4-20 mA 0-20 mA FroM Anfangstemperat. des Analogsignals Messbereichsanfang...
Switzerland TOO WIKA Kazakhstan Manometer AG Brazil Tel.: (+7) 32 72/92 56 38 Tel.: (+41) 41/9 19 72 72 WIKA do Brasil Industria e Comercio Ltda E-Mail: wika-kazakhstan@nursat.kz E-Mail: info@manometer.ch Tel.: (+55) 15-32 66 16 55 E-Mail: wika@splicenet.com.br Korea Taiwan WIKA Korea Ltd.