HL90 EA_de_en_fr.book Seite 52 Freitag, 8. Oktober 2004 12:34 12
Technical data
52
Visit www.butlertechnik.com for more technical information and downloads.
Heater
Type
EC homologation
Model
Heating current
Full load kW
Part load kW
Fuel
Fuel consumption
Full load kg/h (l/h)
Part load % by vol.
Rated voltage
Operating voltage
Rated power consumption
Full load W
(not in starting operation)
Part load W
Max. ambient temperature during operation:
- Heater
- Control unit
- Metering pump
Max. storage temperature:
- Heater
- Control unit
- Metering pump
Max. hot air inlet temperature
Delivery rate for hot air
against 0.5 mbar at
full load
against 0.25 mbar at
part load m
CO
in exhaust gas (at full load):
2
- Permitted function range
CO in exhaust gas - In still air
- At 100 km/h
HC in exhaust gas (at rated load and in still air)
NOx in exhaust gas (at rated load and in still air)
Soot index
- Bacharach method
Heater dimensions:
Length
(tolerance ±3 mm)
Width
Height
Metering pump dimensions:
Length
(tolerance ±3 mm)
Width
Height
Control unit 1561 dimensions:
Length
(tolerance ±3 mm)
Width
Height
Weights:
Heater
Control unit
Metering pump
www.butlertechnik.com
HL 90
HL 90
e1*2001/56*0017*..
Air heater with rotation evaporator
9
6.5
Diesel/heating oil EL
1.00 (1.20)
0.71 (0.86)
V-
12 or 24
V-
10 ... 14.5 or 20.5 ... 29
110
80
°C
-40 ... +50
°C
-40 ... +85
°C
-40 ... +40
°C
-40 ... +85
°C
-40 ... +85
°C
-40 ... +85
°C
+30 max.
3
m
/h
280
3
/h
195
% by vol.
7 ... 10
% by vol.
0.1 max.
% by vol.
0.2 max.
% by vol.
0.01 (100 ppm) max.
% by vol.
0.02 (200 ppm) max.
4.0
mm
650
mm
235
mm
260
mm
113
mm
40
mm
35
mm
97
mm
102
mm
36
kg
13
kg
0.30
kg
0.35
HL 90