Herunterladen Inhalt Inhalt Diese Seite drucken

Butler HL 90 Einbauanweisungen Seite 55

Luftheizgeräte
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

HL90 EA_de_en_fr.book Seite 52 Freitag, 8. Oktober 2004 12:34 12
Technical data
52
Visit www.butlertechnik.com for more technical information and downloads.
Heater
Type
EC homologation
Model
Heating current
Full load kW
Part load kW
Fuel
Fuel consumption
Full load kg/h (l/h)
Part load % by vol.
Rated voltage
Operating voltage
Rated power consumption
Full load W
(not in starting operation)
Part load W
Max. ambient temperature during operation:
- Heater
- Control unit
- Metering pump
Max. storage temperature:
- Heater
- Control unit
- Metering pump
Max. hot air inlet temperature
Delivery rate for hot air
against 0.5 mbar at
full load
against 0.25 mbar at
part load m
CO
in exhaust gas (at full load):
2
- Permitted function range
CO in exhaust gas - In still air
- At 100 km/h
HC in exhaust gas (at rated load and in still air)
NOx in exhaust gas (at rated load and in still air)
Soot index
- Bacharach method
Heater dimensions:
Length
(tolerance ±3 mm)
Width
Height
Metering pump dimensions:
Length
(tolerance ±3 mm)
Width
Height
Control unit 1561 dimensions:
Length
(tolerance ±3 mm)
Width
Height
Weights:
Heater
Control unit
Metering pump
www.butlertechnik.com
HL 90
HL 90
e1*2001/56*0017*..
Air heater with rotation evaporator
9
6.5
Diesel/heating oil EL
1.00 (1.20)
0.71 (0.86)
V-
12 or 24
V-
10 ... 14.5 or 20.5 ... 29
110
80
°C
-40 ... +50
°C
-40 ... +85
°C
-40 ... +40
°C
-40 ... +85
°C
-40 ... +85
°C
-40 ... +85
°C
+30 max.
3
m
/h
280
3
/h
195
% by vol.
7 ... 10
% by vol.
0.1 max.
% by vol.
0.2 max.
% by vol.
0.01 (100 ppm) max.
% by vol.
0.02 (200 ppm) max.
4.0
mm
650
mm
235
mm
260
mm
113
mm
40
mm
35
mm
97
mm
102
mm
36
kg
13
kg
0.30
kg
0.35
HL 90
Inhaltsverzeichnis
loading

Inhaltsverzeichnis