Acumulation Boilers; Electrical Installation - Systempool Luce Vormontage-Installation

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
luce
AcuMulATION BOIleRS
ACUMULATION BOILERS:
For accumulation boilers with capacity lower than 100 l., it is advisable to set the thermostat on the max. value, otherwise the whirpool
will be remarkably shorter.
INSTANT BOILERS:
If an instant boiler or a mixed boiler is available, it must be suitable for the pressure and the consumption indicated before. In case of
capacities lower than 20.000 Kcal/h some functions cannot keep the set temperature, thus causing a flow rate decrease and the temporary
stop of the relevant function.
MIXED TANKS WITH INSTANT BOILER AND ACCUMULATION BOILER:
This is definitely the most suitable system, with a tank capacity not lower than 50 liters.
elecTRIcAl INSTAllATION
SYSTeM-POOl cubicles are designed in line with ceI standards. Also, the cubicles are
thoroughly checked at all stages of the manufacturing process by technical controls to
guarantee maximum quality and complete safety for the user.
Electrical conditions:
SYSTEM-POOL warns that:
* According to electrical safety regulations, the cubicle must be connected to a multipole switch (see illustration) with
a minimum separation between contacts of 3 mm. which shall be installed complying with the electrical safety regula-
tions for bathrooms, and shall take into account the forbidden or protected areas. The switch should be appropriate for
the cubicle voltage and current. It is recommended that the cubicle should be disconnected when not in use (see illustration).
* The bathroom electrical installation shall comply with the relevant country's in force regulations.
* Accessible metal parts which do not belong to the cubicle (heating, water, gas, etc. installations) shall be connected to the equipotential earth
contact.
SYSTeM-POOl accepts no responsibility if the indications in our manuals are not followed.
THE CABLE:
The cable cross section connecting the electrical box to the mains will be 3 x 1,5 mm2 or 3 x 2.5 mm2, according to the consumption shown
on the characteristics plate and type H07VV-F, H07RN-F, H07RR-F, H05VV-F, H05RN-F or
H05RR-F.
ELECTRICAL CONNECTION:
check that the voltage and power frequency coincide with the characteristics shown on the cubicle plate.
To install the cubicle, connect the earth wire (yellow-green) to the earth installation, the blue to Neutral and the black or brown to live. This
connection should always be made in accordance with the standards for bathroom installations. connection to mains shall be through perma-
nent fixed conduit. Also, the cubicle shall be connected to a line featuring a 0,03 A maximum differential circuit breaker and an appropriate
overload differential protection switch. The cubicle earth connection must be executed safely and efficiently. Never handle cubicle electrical
parts when connected.
CABLE OUTLET:
SYSTeM-POOl suggests to arrange the outlet for the cable in the booth in the position (Pos. D) indicated by the symbol (
1.5 m of cable for reaching the booth connection box.
PRe-INSTAllATION MANuAl
3
eN
). leave about