Filter replacement
1. Loosen the metal clips on the side plates of the cas-
sette.
2. Remove the used filter.
3. Insert the new filter in such a way that the IRT logo is
visible from the outside.
4. Push the long edges of the filter into the cassette
grooves.
5. Replace the metal clips.
Attention: The filters are disposable and so should not
be cleaned as this will result in the loss of their filtering
capacity.
9.
UV-lamp replacement
Please contact your distributor and order a UV-lamp
replacementkit including instructions.
Reset Lamp timer
After replacing the lamp a reset of the
[4]
timer needs to be done.
Reset Lamp timer: Make sure that the
[3]
[2]
main switch [5] is turned off. Hold the
Start/Stop button [1] and top right but-
ton [2] pressed in simultaneously while
the main switch [5] is turned on. Keep
the buttons pressed in until a confirma-
[1]
tion message (L1--rESEt.) appears in the
top display [4].
[5]
10. Trouble shooting
Problem
The UVA lamps starts up but shuts down automatically
after a while.
Possible solution
The lamp is worn out. Please contact your distributor and
order a new one.
Problem
The lamp doesn´t start.
Possible solution
Ensure that required cooling time for lamps is fulfilled.
Cooling time increases with dirty air filter.
714598 rev 5
11. EC Declaration of conformity
According to testing institutes and according to the
machine directive the IRT products in this manual are not
defined as machines, wherefore the machine directive
reference cannot be included in this declaration.
In accordance with EN 17050-1:2010
We,
Hedson Technologies AB
Box 1530
SE-462 28 VÄNERSBORG
Sweden
declare under our sole responsibility that the product
IRT-UVA 1 PrepCure 3 Digital
to which this declaration relates is in conformity with the
following standards
EN 60204-1
Safety of machinery
EN 61000-6-3
Electro-magnetic Compatibility,
Generic Emission Standard.
EN 61000-6-2
Electro-magnetic Compatibility,
Generic Immunity Standard.
EN 61000-3-2
Electromagnetic Compatibility
EN61000-3-4
Electromagnetic Compatibility
EN ISO 9001
Quality Management System
in accordance with the provisions of the following
directives in their most current version
2014/35/EU
Low Voltage Directive
2014/30/EU
Electro-magnetic Compatibility
Directive
2011/65/EU
Restriction of the use of certain
hazardous substances (RoHS)
Arlöv Sweden, April 21 st 2016