Herunterladen Inhalt Inhalt Diese Seite drucken

Control Panel - siegling blizzard HC 120/40 Betriebsanleitung

Heizzange
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.5 Control panel

Fig. 3.5.1 – Control panel
9
"ON/OFF" button > hold down to switch the device on or off.
The device is now in start mode.
"SELECT" button > press briefly to start setting mode. Press briefly again
to run through the three adjustable parameters for the heating
clamp in a sequential loop.
Heating temperature [°C or °F]
Holding time
Cooling temperature [°C or °F]
hold down to toggle between the units used
(from "°C" to "°F" or vice versa) for the parameter displayed.
"CONFIRM" >
press briefly
– to save the previously entered parameter values in setting mode
and to terminate setting mode,
or
– to save the previously entered calibration values in calibration mode
and to terminate calibration mode,
or
– to terminate heating up mode and start heating mode
or
– to stop the countdown during holding time.
The countdown continues when the button is pressed again or
automatically after 60 seconds.
The function executed depends on the operating mode.
"+" or "–" button >
press briefly
to change the displayed parameter in small increments
(1 °C/°F or 10 s),
hold down
to change the displayed parameter in large increments
(5 °C/°F or 1 min).
(Only active in setting mode after pressing the "SeLeCT" button.)
"+" and "–" button > hold down
to put the device in calibration mode.
[s]

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis