Heizzange
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.3 Check and adjust heating parameters
To do this, the heating clamp must be in start mode. See Section 3.
Stop
During operation the heating plates on the heating clamp (1) and the inserted splice guide (2) may reach a temperature of
210 °C. Injury may occur. (Fig. 2.2.1)
– Briefly press the "SeLeCT" button to switch to setting mode.
Briefly pressing the "SeLeCT" button again displays the adjustable heating parameters in sequence.
Order: > Heating temperature [°C or °F]
> Holding time [s]
> Cooling temperature [°C or °F]
This loop can be repeated as many times as desired.
Holding down the "SeLeCT" button toggles between "°C" and "°F".
Pressing the "+" or "–" button changes the value that is displayed.
Heating temperature:
press briefly > changes by 1 °C/°F
Holding time:
press briefly > changes by 10 s
Cooling temperature:
press briefly > changes by 1 °C/°F
Note
When setting the heating parameter and no entry is made within 3 seconds, the device switches back to start mode.
– Press the "COnFIRM" button to save the previously entered heating parameters and terminate setting mode.
The device now starts automatically in heating mode.
11
hold down > changes by 5 °C/°F
hold down > changes by 1 min
hold down > changes by 5 °C/°F